a Citrin/Pompei canopy includes:
4 screws
2 metre flex hose
4 cover plugs
OBS! Electrical installations must be carried out by an official electrician.
To mount the canopy the following must be done: connection to the outside must be
established, either through ceiling or wall.
Electrical connection (230 V)
The cable must be led alongside the flex hose to the electrical supply.
assembly
Use the specified measurements (fig. 1) and mark off the cutout under the shelf (fig. 2, article 1).
*Note Interior measurements in the cabinet may vary.
Use a jigsaw (fig. 2, article 2) and cut a hole in the shelf above (fig. 2, article 3) so that a
flex hose can be led through.
flex hose assembly
Attach the flex hose to the extractor with PVC tape/straps (fig. 3, articles 1 and 2).
Next, lead the flex hose through the shelf (if necessary) and the hole (fig. 3, article 3) and
assemble it to the exhaustion flange on a roof fan, ceiling fan or on an exterior wall fan.
Next, hold the canopy up against the back wall and drill 4 x holes.
Attach the canopy via the 4 included screws and plug in the 4 included cover plugs (fig. 4).
assembly of filter
Mount the filter using the included finger screw.