Application
Operation is possible in conjunction with:
- Pressurized storage heaters
Operation is not possible with:
- Low-pressure storage heaters
(displacement water heaters)
Specifications
• Flow rate at 60 psi flow pressure:
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
• Thermal desinfection possible
Note:
- Major pressure differences between cold and hot water
supply should be avoided.
Installation
Refer to the dimensional drawings on fold-out page I.
For deviation to the suggested installation, observe minimum
clearance required for escutcheon sizes.
Flush piping system prior and after installation of faucet
thoroughly!
Side valves, see fold-out page III, fig. [1].
• Valve with a groove on the top edge of the cartridge (A) and
in addition marked with COLD should be mounted on the
right (cold water) side.
• Valve without a groove on the top edge of the cartridge (A)
and in addition marked HOT should be mounted on the left
(hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the
side valve (C).
Make sure that the rubber washer (B1) is on the top of the
fiber washer (B2).
2. Insert the side valve (C) through the basin hole from below.
3. Close the headparts (clockwise for the hot side and counter-
clockwise for the cold side).
4. Place the escutcheon O-ring (D) on the basin and screw
down the handle with escutcheon (E) until it stops.
Be sure that the handle points away from the spout.
5. Tighten the mounting set (B) from below to secure the valve.
1
English
approx. 4.5 L/min or 1.2 gpm
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
158 °F
cold - Right hand
hot - Left hand
Spout, see fig. [2] to [4].
1. Place the escutcheon (G) and the ring (H) on the spout (I)
from bottom, observe the right position of the ring (H), and
insert the spout (I) through the basin hole from above, see
fig. [2].
2. Place the fastening set (J) against the bottom of the basin
and fasten with nut (K). Tighten nut (K) with a 23mm
wrench.
3. Insert the lift rod (F) through the spout.
4. Connect flexible hoses (L) to the side valves, see figs. [3]
and [4].
Mount pop-up drain, see fold-out pages II and III, fig. [5].
Ensure that flange of pop-up drain is sealed.
Connect wideset
Connect the side valves to the water supply.
Insure the supplied washers are used for all connections.
The cold water supply should be connected on the right side
valve (marked COLD) and the hot water supply to the left valve
(marked HOT).
Open cold and hot water supply and check connections
for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off cold and hot water supply.
I. Ceramic cartridge, see fig [6].
Secure side valve against sliding back!
1. Remove handle (E).
2. Unscrew the ceramic cartridge (A) using a 17mm wrench.
3. Change complete ceramic cartridge (A) or O-ring (A1).
Observe the different replacement part numbers of the
cartridges.
II. Flow straightener, see fold-out page II.
Unscrew and clean flow straightener (48 270).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.