Operation (con't)
Figure 32
Create Whip Processing File:
1. To create a whip processing file click the button
Create Whip Processing File.
2. Enter a file name in the top left text box to save your
new Whip Processing File under.
3. Select a file location to save your Whip Processing
File to. Click the Directory button to open a dialog
window that will allow you to choose where you
would like to save the Whip Processing File. This
should be a removable USB Drive so that the files
can be easily transferred to the C3.
4. Type your desired whip parameters (Whip Length,
Lead Length, Tail Length and #of Whips) for the
first whip into the blue header box and then click the
green ADD button to add those whip parameters to
the table.
Figure 33
Note: The whip length must be greater than or equal
to 12 inches. The total of the lead length plus the
tail length cannot exceed the whip length minus 4
inches. If this is violated then the invalid parameters
will be highlighted yellow in the table.
Greenlee Tools, Inc.
C3 Auto Whip Clad Cable Cutter
5. Continue entering whip parameters and clicking the
add button for each whip you would like to store as
a part of that file.
6. If you make an error when entering the values you
can simply click the box with the error and correct
its value in the table and then press enter.
7. To delete an entire row click the row number and
then click the DELETE ROW button to remove that
entire row.
8. When you are finished adding rows and making
changes to the Whip Processing File click the Save
File button to save the file to the destination folder
you specified in step 3.
9. When you are finished using the software click the
MAIN MENU button and then click the EXIT button.
You can also simply hit the X in the top right corner
of the window. Be sure all work is saved before
exiting.
Editing an existing Whip Processing File:
1. From the main menu click the Create Whip
Processing File.
2. Click the green OPEN FILE button.
3. Navigate through the file browser to find your
previously saved Whip Processing File.
4. Double click on the desired file and it will open in
the application.
21