WIRING CONNECTIONS
All wiring must comply with local codes and unit must
be properly grounded.
1. While making wiring connections, support the heater
assembly on the bottom of the rough-in frame.
2. For 120 Volt operation, make wiring connections as
shown in Figure 4.
3. For 240 Volt operation, make wiring connections as
shown in Figure 5.
4. Use wire nuts to make connections. Insulate all
connections with electrical tape.
SECURING THE HEATER
1. Dress all wiring back to into junction box.
2. Locate center holes in housing flange and align with
mounting holes in grille.
3. Use two provided screws to attach grille to housing.
OPERATION
Turn thermostat fully clockwise to HIGH position. Allow
heater to run until room is at desired temperature. Adjust
thermostat as required to maintain desired temperature. Turn
the thermostat to FULL COUNTERCLOCKWISE position
when operation is no longer desired.
Thermal protector: If for any reason temperatures increase beyond normal limits, a safety thermal fuse will shut heater off. The
heater will require servicing by a qualified electrician.
Check entire installation to determine cause of overheating.
SERVICE PARTS
Key No.
Part No.
1
99111432
2
99360253
3
52872039
4
97018465
97018466
5
57271000
6
33384000
7
33178000
8
61962000
9
35841000
5
1
3
2
Description
Grille
Knob
Grille Screw
Heater Assembly (9810WH)
Heater Assembly (9815WH)
Thermostat, with Mounting Nut
Thermostat Cover
Blower & Motor
Heat Box
Thermal Fuse (2 required)
8
7
9
6
4
120vAC
GREEN
GROUND
4
YELLOW
3
WHITE
2
RED
1
BLACK
240vAC
GREEN
GROUND
4
YELLOW
3
WHITE
NO
2
RED
CONNECTION
1
BLACK
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a pe-
riod of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR-
TICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under normal
use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START-
ERS AND TUBES. This warranty does not cover (a) normal maintenance and
service or (b) any products or parts which have been subject to misuse, negli-
gence, accident, improper maintenance or repair (other than by Broan-NuTone),
faulty installation or installation contrary to recommended installation instruc-
tions.
The duration of any implied warranty is limited to the one-year period as speci-
fied for the express warranty. Some states do not allow limitation on how long an
implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLU-
SIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT
BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR-
MANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you.
This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address
or telephone number below, (b) give the model number and part identification
and (c) describe the nature of any defect in the product or part. At the time of
requesting warranty service, you must present evidence of the original purchase
date.
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
GREEN OR BARE
GROUND
WHITE
BLACK
FIGURE 4
GREEN OR BARE
GROUND
RED OR WHITE
NO
CONNECTION
BLACK
FIGURE 5
99044691A