Unit connectors
Network - RJ-45 Ethernet connector. Supports PoE (Power over Ethernet, class 3). Using shielded
cables is recommended.
Audio in - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used
from a stereo signal). An external microphone must be used to for audio detection.
Audio out - 3.5 mm output for audio (line level), can be connected to a public address (PA) system
or an active speaker with a built-in amplifier. A pair of headphones can also be connected. A stereo
connector must be used for audio out.
RS-485/422 - two 2-pin terminal blocks for RS-485/422 serial interface used to control auxiliary
equipment, e.g. PTZ devices.
The RS-485/422 serial port can be configured in the following port modes:
•
Bidirectional RS-485 half-duplex port for data transmission using two
wires, one combined RX/TX pair.
•
Bidirectional RS-485 full-duplex port for data transmission using four
wires, one RX pair and one TX pair.
•
Unidirectional RS-422 port for transmitting or receiving data using two
wires, RX- or TX pair.
•
Bidirectional RS-422 full-duplex port for data transmission (point-to-point) using four
wires, one RX pair and one TX pair.
Function
RS 485/422TX(A)
RS 485/422TX(B)
RS-485A alt RS-485/422RX(A)
RS-485B alt RS-485/422RX(B)
SDHC memory card slot - High capacity SD memory card used for local recording and removable
storage.
Power - 3-pin terminal block 8-20 V DC or 20-24 V AC.
Model
AXIS Q1910
AXIS Q1910-E
AXIS Q1921
AXIS Q1921-E
!
CAUTION! - Incorrect connection of the wires could cause damage to the camera.
Pin
Notes
1
TX pair for RS-422 and 4-wire RS-485
2
3
RX pair for all modes (combined RX/TX for 2-wire RS-485)
4
DC power input
8-20 V DC, max 8.2 W
8-20 V DC, max 11.2 W
8-20 V DC, max 6 W
8-20 V DC, max 10 W
AXIS Q1910/-E/AXIS Q1921/-E Installation Guide
AC power input
20-24 V AC, max 12.7 VA
20-24 V AC, max 17.4 VA
20-24 V AC, max 10 VA
20-24 V AC, max 16 VA
RS-485/422
RX/TX
TX
4 3
2 1
AC
DC