English
Diagram Reference
Wireless Displacement Detector
Appearance
1
1
Indicator
Alarm Detection:
Product Information
Alarm Occurs- Red light flashes 2 times.
Delayed Alarm Triggered - Red light flashes once.
Display Signal Strength:
COPYRIGHT ©2018 Hangzhou Hikvision Digital
Under the signal strength checking mode:
Technology Co., Ltd.
Green - Strong Signal
ALL RIGHTS RESERVED.
Red - Weak Signal
Any and all information, including, among others,
Reset Button
wordings, pictures, graphs are the properties of
2
Hangzhou Hikvision Digital Technology Co., Ltd. or its
After the device being powered off, hold the reset button. Power
the device on.
subsidiaries (hereinafter referred to be "Hikvision").
The red LED flashes 3 times when the formatting is completed.
This user manual (hereinafter referred to be "the
Manual") cannot be reproduced, changed,
translated, or distributed, partially or wholly, by any
3
DIP Switch
means, without the prior written permission of
-Indicator On/Off
Hikvision. Unless otherwise stipulated, Hikvision
-Sensitivity Settings
does not make any warranties, guarantees or
Tamper
representations, express or implied, regarding to the
If the detector is disassembled, an alarm will be triggered.
Manual.
DIP Switch
2
Set the DIP before power on for the first time use.
About this Manual
Loosen the set screws and disassemble the device.
This Manual is applicable to Control Panel
Remve the front panel.
The Manual includes instructions for using and
Note: Do not disassemble the device with sharps.
managing the product. Pictures, charts, images and
a
Indicator On/Off
all other information hereinafter are for description
Set the bit 1 for turning on/off the indicator.
and explanation only. The information contained in
Sensitivity
b
the Manual is subject to change, without notice, due
to firmware updates or other reasons. Please find
Set the bit 2 and bit 3 for sensitivity.
Bit 2: Alarm Time Settings
the latest version in the company website
(http://overseas.hikvision.com/en/).
Bit 3: Delayed Alarm Settings.
Please use this user manual under the guidance of
If the detector keeps static for 3s after a movement is detected, the
professionals.
alarm will not be triggered. Otherwise the alarm will be triggered.
1)
Alarm Triggered after Moving for 1s to 2s (Without Delay for 3s)
Trademarks Acknowledgement and other
2)
Alarm Triggered after Moving for 3s to 4s (Without Delay for 3s)
3)
Alarm Triggered after Moving for 1s to 2s (With Delay for 3s)
Hikvision's trademarks and logos are the properties of
4)
Alarm Triggered after Moving for 3s to 4s (With Delay for 3s)
Hikvision in various jurisdictions. Other trademarks and
Detector Power On
3
logos mentioned below are the properties of their
Remove the insulating strip to power on the detector.
respective owners.
The detector will enter the test mode after powering on. The indicator
will flash in red and green alternatively. Do not move the detector
during the test. After the test is finished, the indicator will be turned off.
Legal Disclaimer
Indicator Color: R=Red, G=Green
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
Detector Registration
4
LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE,
SOFTWARE AND FIRMWARE, IS PROVIDED "AS IS", WITH
a
Register the Detector Locally
Power on the security control panel. Press the function button once
ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO
and shake the detector. And you can add the detector accroding to
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
the voice prompt. The green LED of the detector will flash 8 times
WITHOUT LIMITATION, MERCHANTABILITY,
after being successfully added.
Note: The distance between the security control panel and the detector should be
SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR
less than 50 cm.
PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY.
b
Register the Detector via APP
IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
1. Log in to the APP Store and input "Hik-Connect" to search the mobile client.
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU
2. Download and install Hik-Connect to your phone.
3. After installing, tap
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR
4. Power on the security control panel.
INDIRECT DAMAGES, INCLUDING, AMONG OTHERS,
5. Log in the Hik-Connect and ap the icon "+" at the upper-right coner of the
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
Hik-Connect page to add the security control panel. You can scan the QR code
INTERRUPTION, OR LOSS OF DATA OR
on the device rear panel or on the package box, or input the device serial No.
manually to add the device when the device is in the registration mode.
6. After adding the security control panel, tap the arming status icon on the
DOCUMENTATION, IN CONNECTION WITH THE USE
right of the security control panel's name to enter the Partition page.
OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN
7. Tap the "+" icon on the Partition page to add the peripherals.
Detector Installation
5
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
1. Check Signal Strength
REGARDING TO THE PRODUCT WITH INTERNET
Enter the signal checking mode by operating on the control panel.
ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY
Detector indicator turns green: Strong Signal.
AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE
Detector indicator turns red: Weak Signal
2. Install the Detector
ANY RESPONSIBILITES FOR ABNORMAL OPERATION,
Paste the sponge tape on the rear side of the detector.
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING
Paste the detector on the required place.
FROM CYBER ATTACK, HACKER ATTACK, VIRUS
Note: To make the TAMPER work properly, the thickness of the sponge tape
should be no more than 1mm.
INSPECTION, OR OTHER INTERNET SECURITY RISKS;
HOWEVER, HIKVISION WILL PROVIDE TIMELY
Specification
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION.
PLEASE CHECK ALL RELEVANT LAWS IN YOUR
JURISDICTION BEFORE USING THIS PRODUCT IN
ORDER TO ENSURE THAT YOUR USE CONFORMS
THE APPLICABLE LAW. HIKVISION SHALL NOT BE
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED
WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS
MANUAL AND THE APPLICABLE LAW, THE LATER
PREVAILS.
1
3
to run the client.
3
5
Wireless Displacement Detector
RF Frequency
433MHz
RF Modulation
FSK
Transmission Speed
10.0kbps
Battery
CR2450
Internal Button
1
Tamper
Internal tamper
Indicator
1 (Dual-LED)
1 for indicator control
DIP Switch
2 for sensitivity settings
Material
Nonmetal; PC+ABS
Installation Environment
Indoor/Outdoor
Temperature
–10 ℃ to 55 ℃
Humidity
10% to 90%
Protection Level
IP66
Dimension (W*H*D)
31mm*60mm*10mm
Weight
22.0g
Installation Type
Tap
1
2
3
a
ON
OFF
G
R
10
31
1mm
2
1)
b
3)
4
CONTROL
PANEL
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the RE Directive
2014/53/EU, the RoHS Directive 2011/65/EU.
2)
4)