6 - Technical characteristics
• 230 V, 50 Hz power supply, ±10%
• Power consumption: 4 VA
• Class II insulation
• Load shedding on up to 8 channels
• Transmission frequency: 132.5 kHz, FSK modulation
• Transmission power conforms to the CENELEC NF 50065 standard, class 122
• 1 remote information bus input (output from the electronic meter)
• Connection with the meter: 1 6/10 single twisted pair cable with continuity wire,
max. length 100 m
• 1 off-peak hours contact phase input (conventional meter)
• Dimensions: 4 modules, h= 53 mm
• Cascade or cascadocyclique
• Circuit-breaker calibres (conventional meter) from 10 A to 90 A
• Type 1.C automatic action (brownout)
• Installation in an environment with normal pollution levels
• Operating temperature: 0°C to +40°C
• Storage temperature: -10°C to +70°C
• DHW output: 230 V / 2 A
Current Transformer
• Maximum permissible current: 100 A
• No particular direction of assembly or polarity
• Connection: cable with minimum cross-section 0.75 mm
7 - Maintenance
No LED comes on.
The LED
flashes red.
The green OK LED flashes.
®
load shedding
Diagnosis / Solutions
There is no power supply.
Check your circuit breaker.
Faulty dialogue with meter.
Check the connection or contact your installer.
The GP6CPL is not configured
Exit configuration mode or configure your appliance by pressing
the
button.
- 25 -
2
, max. length 2 m
EN