Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
Specifications
• Max. flow
EcoJoy
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection:
• Deck thickness max.
• Non reversible cartridge
Notes:
- Major pressure differences between cold and hot water supply
should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable appliances.
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Mount sink faucet, see Fig. [1].
Refer to the dimensional drawing on page 1.
Feed the spray hose (A) through the faucet body from above, see
Fig. [1].
Note:
If brace (B) is omitted, deck thickness can be increased by 9/16" to
a total of 2 3/8".
Connect sink faucet, see Figs. [1] and [2].
- Cold water connection
- Hot water connection
Avoid cross connection. The cartridge is not reversible.
Connect the spray hose (A), see Fig. [3].
1. Connect the handspray (C) without using any additional seals.
2. Fit one side of the stop (D) and spring (E) over the spray
hose (A) from below.
3. Pass the end of the spray hose (A) through the other hole in the
stop (D).
4. Install the snap coupling (G) on the end of the spray hose (A) and
tighten by hand.
5. Push the sleeve (J) of the snap coupling (G) downwards and fit
the coupling to the union (K)
To ensure that the handspray (C) is correctly seated when inserted,
lug (L) and (M) on the outlet must engage in recess on the
handspray.
Open cold and hot-water supply and check connections for
leakage!
8.3 L/min or 2.2 gpm/60 psi
5.7 L/min or 1.5 gpm/60 psi
14.5 - 72.5 psi
cold - RH
= right
= left
English
Operation
1. Lever
Lift lever
Press lever down
Move lever to right
Move lever to left
2. Handspray
Lift lever (faucet open). The water will always emerge first from the
aerator.
For using the handspray, see Fig. [4].
Turning off the faucet automatically diverts the water flow from
handspray to aerator.
7.25 psi
Flow rate limiter
145 psi
This faucet is fitted out with a flow rate limiter, permitting an
232 psi
infinitely individual variable reduction of the flow rate. The highest
possible flow rate is set by the plant before despatch.
176 °F
The use of flow rate limiters in combination with hydraulic
hot - LH
instantaneous water heaters is not recommended.
2 3/8"
To activate see "Replacing the cartridge" point 1 to 4,
Figs. [5] and [6].
Maintenance
Inspect and clean all parts, replace as necessary and grease with
special grease.
Shut off cold and hot water supply!
I. Replacing the cartridge, see Fig. [5].
1. Lever out plug (N).
2. Loosen set screw (O) using a 3mm allen wrench.
3. Pull off lever (P).
4. Unscrew cap (R).
5. Remove screw coupling (S) and detach complete cartridge (T).
6. Replace complete cartridge (T).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves on the
housing. Tighten screw coupling (S) until it turns freely.
II.Strainer and rose, see Fig. [7].
1. Unscrew handspray (C) and remove filter (U) and check
valve (V).
2. Pull out ring (W1) and unscrew rose (W) by using wrench (W2).
3. Clean strainer (X) and rose (W).
4. With SpeedClean nozzles simply rub fingers over rose to remove
limescale.
We guarantee that the SpeedClean nozzles will function
unchanged for a period of five years.
Assemble in reverse order.
Replacement parts, see page 2 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
= open (water flow)
= closed (off)
= cold water
= hot water
4