Compressor 1.5Hp - 1100W - 24L
The numbers in the following text correspond
with the pictures at page 1 - 4.
Read the operating instructions carefully
before using this device. Familiarise
yourself with its functions and basic
operation. Service the device as per the
instructions to ensure that it always
functions properly. The operating
instructions and the accompanying
documentation must be kept in the vicinity
of the device.
Contents
1. Machine details
2. Safety instructions
3. Use
4. Maintenance
1. machine details
Technical specifications
Voltage
Frequency
Capacity
Idling speed
IP Class
Tank contents
Air intake
Max. outlet pressure
Weight
Sound power level
The value of the noise level may rise from 1 to 10
dB(A) as a function of the environment in which
the compressor will be installed.
product information
Fig. A
1
Cover
2. Handle
3. Switch button
4. Automatic stop switch
5. Pressure regulator
6. Quick coupler (outlet)
7. Quick coupler (outlet regulated pressure)
8. Pressure gauge (tank pressure)
9. Pressure gauge regulated pressure
10. Drain cock
11. Wheel
12. Rubber feet
Ferm
13. Tank
14. Air filter
15. Overload switch
16. Quick coupler (tank outlet pressure)
2. safety instructions
explanation of symbols
230 V~
50 Hz
1.5 hp (1100 W)
2850/min
IP 20
24litre
special safety instructions
161 l/min
•
Warning! The compressor may only be used
8.0 Bar
22.7 kg
in suitable rooms (with good ventilation and an
93.0 dB (A)
ambient temperature from +0°C to +40°C).
•
Check that the tank is fully decompressed
before connections with the tank are
unscrewed.
•
It is prohibited to make holes in, or welds to, or
purposely to distort the compressed air tank.
•
Do not perform any actions on the compressor
without first having taken the power plug out of
the plug socket.
•
Do not aim water jets or jets of flammable
liquids at the compressor.
•
Do not place flammable objects near the
compressor.
•
Switch the switch (3) to the "0" position (OFF)
during dwell time (fig. 11).
•
Never aim the air jet at persons or animals (fig.
20).
•
Do not transport the compressor with the tank
pressurised.
•
N.B.: some parts of the compressor such as
Denotes risk of personal injury, loss of life
or damage to the tool in case of non-
observance of the instructions in this
manual.
Risk of electric shock.
Caution: the compressor could start
automatically in case of a black-out and
subsequent reset
Wear ear protection.
Sound power level
EN
5