Electric Connections - Quick KTB4 Manual De Instalacion Y Uso

Ocultar thumbs Ver también para KTB4:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ELECTRIC CONNECTIONS

The interface complies with EMC standards (electromagnetic compatibility) but requires correct installation to
avoid compromising its performance and that of the instruments in the vicinity.
For this reason the cables of the interface must be positioned at a distance of at least:
• 1 m away from cables that carry radio signals (except for SSB radio transmitters).
• 2 m away from cables that carry SSB radio transmitter radio signals.
Follow the rules below to construct the electrical plant relative to the interface:
• Before switching on the power to the interface, check that all the electrical connections are correct.
• Insert a switch to switch the interface on and off.
• Insert a fast-acting 100 mA fuse on the power line to the interface.
• Use an unscreened cable with a braided pair (cross section 0.25/ 0.35 mm2 AWG 22/24, impedance 100/150
ohm) for data interface connection (CANH and CANL signals).
• The KTBS sensor has no polarity, therefore the wires CAN be connected in any order.
• The data cable cannot be more than 100 meters long.
There are two terminal clamps on the interface for the various connections to the electrical signals:
TERMINAL BLOCK M1
SIGNAL
+ V SUPPLY (+)
- V SUPPLY (-)
CANH (H)
CANL (L)
TERMINAL BLOCK M2
SIGNAL
SENS1
SENS2
SENS3
SENS4
KTB4N - REV001A
DESCRIPTION
Instrument positive power supply
Instrument negative power supply
CAN interface
CAN interface
DESCRIPTION
KTBS sensor 1
KTBS sensor 2
KTBS sensor 3
KTBS sensor 4
INSTALLATION
GB
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ktb4n

Tabla de contenido