INSTALLATIoN MANUAL
CAA470A
2-Door expansion module
The reader LEDs can be used to verify the reader's connections and programming. If no flashing occurs when
a card is presented to the reader, the reader may be installed incorrectly. A short flash indicates that the reader
is correctly installed, but the card is the wrong type or that the reader was incorrectly programmed.
Electromagnetic
LOCK 2
D1NC
COM
D1NO
D2NC
COM
D2NO
Z1
COM
Z2
Z3
COM
Z4
BACKUP
2
1
0
0
NO CARD
0
1
2 CARDS
1
0
ALL CARDS
1
1
UNLOCK DOOR
GALEO/W
WIEGAND
KEYPAD 2
The 2-Door expansion module (CAA470A) does not support zone doubling.
NC INPUT
CONNECTION
OR

JUMPEr SETTINGS

1
BATTErY CHArGING
Charging the battery at 350mA (jumper ON) takes longer,
but consumes less power. Charging the battery at 700mA
(jumper OFF) takes less time, but consumes more power.
2
HIGH/LoW BIAS
Place the A+ and B- jumpers on LOW only if the 2-Door
Expansion Module is at the beginning (Start Point) of the E-bus
Network. Otherwise, place the A+ and B- jumpers on HIGH
3
EoL
Place the EOL jumper ON if the 2-Door Expansion Module is
at the Start Point or at the End Point of the E-bus Network.
Otherwise, place the EOL jumper OFF.
10
cdvigroup.com
Figure 6: Connection drawing of the CAA470A
Always consult the
External Power Supply
regulatory agency in your
12 - 24Vdc
area for existing regulations
-
+
regarding doors designated
as emergency exits.
Pull
Station
Transformer 16VAC-40VA
-
+
(Europe: CDVI TR1640 recommended)
EMERGENCY
(UL/ULC: CDVI150 or CDVI200
recommended)
PULL
DOWN
Do not connect to a
receptacle controlled by
a switch.
CAA470A
2-Door Expansion Module
LOCK#1
1
STATUS
JP120
LOCK#2
350mA/700mA
SWITCH
SW1
ADD 1
ADD 2
SW2
L1Energize
SW3
SW4
L2Energize
4
SW5
BACKUP1
SW6
BACKUP2
PULSE 5&6
SW7
5
N/D
SW8
READER#2
DATA
KEYPAD 2
Buzzer wire
to OUT6
WIEGAND READER 1
2R CONNECTION
3R CONNECTION
Input 1
Input 1
1KΩ
1KΩ
OR
Door Strike LOCK 1
CDV I
TR16/4 0
BAT+
+
BAT-
AC OK
AUX OK
COMM
CHECK BATT
BATT TRBL
OUT5
OUT6
2
LOW HIGH
B-
3
A+
GND
READER#1
TMP
DATA
TMP
EOL
TX RX
E-BUS
KEYPAD 1
Buzzer wire
to OUT5
EOL
1KΩ

DIP SWITCH SETTINGS

4
1
1
OFF
2
oN
3
OFF
12Vdc
Installation must comply
with local codes and
ordinances.
GEL Type Battery
12Vdc - 7Ah
(Europe: CDVI B7AH recommended)
(UL/ULC: YUASA #NP7-12 recommended)
Permitted Replacements:
Various (means any type, from any
manufacturer that complies with
the "Technical Data and
securement means" and meets the
"Mark of conformity" can be used).
AC
AC
V+
V+
V-
V-
To WIEGAND READER 1
Buzzer
To GALEO/W WIEGAND
KEYPAD 2 Buzzer
E-BUS :
A+
To CTV900A or
B-
other expansion
modules
Connect to enclosure's
tamper switch (N.C.)
Reader and keypad wiring
may differ from the
diagram. Please consult
your dealer for details.
ADD1 and ADD2 determine the 2-Door
Expansion Module's address, regardless of the
order that they are connected to the controller.
2
3
4
5
6
OFF
BACKUP 1 & 2
5
OFF
determine what the
oN
CAA470A will do in
stand-alone mode
EN
ON
OFF
7
8