CDVI CAA470A Manual De Instalación página 9

Módulo expansor de 2 puertas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATIoN MANUAL
CAA470A
2-Door expansion module
the beginning (Start Point) of the E-bus
Network. Otherwise, place the A+ and B-
BIAS jumpers on HIGH (see Figure 2 and
Figure 3).
Figure 3: Setting the BIAS A+ and BIAS B- jumpers
Jumpers
set to LOW
LOW
HIGH
B-
A+
350mA/700mA Battery
Charging Jumper
The 350mA/700mA Jumper allows you to
select the charging current for the backup
battery of the 2-Door Expansion Module.
Charging the battery at 350mA takes
longer, but consumes less power. Charging
the battery at 700mA takes less time, but
consumes more power.
Figure 4: Setting the 350mA/700mA jumper
Jumper set to
350mA
Programming in Centaur
Using the Centaur Access Control Software,
program the inputs, outputs, readers, and
keypads connected to the 2-Door Expansion
Green "lock#1" and "lock#2" LEDs:
ON = Relay activated.
CAA470A
2-Door Expansion Module
LOCK#1
STATUS
D1NC
COM
JP120
LOCK#2
D1NO
350mA/700mA
D2NC
COM
D2NO
Z1
COM
Z2
Z3
COM
READER#2
Z4
BACKUP
DATA
2
1
0
0
NO CARD
0
1
2 CARDS
1
0
ALL CARDS
1
1
UNLOCK DOOR
Green "READER#2 data" and "READER#1 data" LED:
Long flash = Receiving card data
Short flash = Receiving card data but unknown or invalid format
OFF = Not receiving card data
Jumpers
set to HIGH
LOW
HIGH
B-
A+
Jumper set to
700mA
Figure 5: CAA470A indicators
Green "STATUS" LED:
1-second flash = Module OK
Slow flash = Communication failure
(see also "COMM" LED)
+
AC OK
AUX OK
COMM
CHECK BATT
BATT TRBL
SWITCH
SW1
ADD 1
SW2
ADD 2
SW3
L1Energize
SW4
L2Energize
SW5
BACKUP1
SW6
BACKUP2
LOW HIGH
SW7
PULSE 5&6
B-
N/D
SW8
A+
READER#1
DATA
EOL
TX RX
E-BUS
Module. The options are explained in the
Centaur Access Control Software Reference
Manual. Centaur will identify the 2-Door
Expansion Module by its address (defined by
the DIP Switches 1 & 2) and will recognize
the devices as follow:
Doors
Keypad/Reader 1
Keypad/Reader 2
Inputs
Z1
Z2
Z3
Z4
outputs
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
AC
AC
BAT+
BAT-
V+
V+
V-
V-
OUT5
OUT6
Red "TX" LED and
green "RX" LED:
A+
B-
Brief or steady ON =
GND
TMP
Communication OK
TMP
OFF = Communication
failure
Address 1 Address 2 Address 3
Door 3
Door 5
Door 7
Door 4
Door 6
Door 8
Input 17
Input 21
Input 25
Input 18
Input 22
Input 26
Input 19
Input 23
Input 27
Input 20
Input 24
Input 28
Output 7
Output 13
Output 19
Output 8
Output 14
Output 20
Output 9
Output 15
Output 21
Output 10
Output 16
Output 22
Output 11
Output 17
Output 23
Output 12
Output 18
Output 24
Doors cannot be defined as Door
Type Elevator (Door Properties
window, General tab, Door Type:
Elevator) and the module does
not support Interlock Inputs (Door
Properties window, Inputs and
outputs tab, Interlock Input).
Other modules in the system cannot
activate the 2-Door Expansion
Module's outputs. The 2-Door
Expansion Module does not support
Zone Doubling (see Figure 6).
Green "AC oK" LED:
ON = AC power
OFF = Power failure
Green "AUx oK" LED:
ON = Auxiliary power
OFF = Auxiliary power failure
red "CoMM" LED:
ON = Communication failure
OFF = OK
Green "CHECK BATT" LED:
ON = Battery verification in
progress (every minute)
red "BATT TrBL" LED:
ON = Battery low or
disconnected
cdvigroup.com
EN
9

Publicidad

Tabla de contenido
loading

Productos relacionados para CDVI CAA470A

Tabla de contenido