2. TECHNICAL DATA
2.1. HEAT EXCHANGER
MODEL
WATERHEAT 20kW
WATERHEAT 40kW
WATERHEAT 60kW
WATERHEAT 105kW
WATERHEAT 140kW
WATERHEAT 210kW
WATERHEAT EQUIPADO 20kW
WATERHEAT EQUIPADO 40kW
WATERHEAT EQUIPADO 60kW
3. INSTALLATION/ASSEMBLY
3.1. TRANSPORTATION/STORAGE
Transport the heat exchanger only after being drained.
Store the drained heat exchanger in indoor locations with a non aggressive atmosphere.
3.2. ASSEMBLY DIMENSIONS
MODEL
CODE
WATERHEAT 20kW
41426
41427
WATERHEAT 40kW
41428
WATERHEAT 60kW
65539
WATERHEAT 105kW
65540
WATERHEAT 140kW
WATERHEAT 210kW
65541
Capacity: kW
CODE
90°C
60°C
41426
20
10
41427
40
20
41428
60
30
65539
105
40
65540
140
60
65541
210
80
43506
20
10
43507
40
20
43508
60
30
DIMENSIONS (mm)
A
B
C
D
293 129
120
1 ½" ¾"
388 129
215
1 ½" ¾"
509 129
336
1 ½" ¾"
680 190
423
2"
965 190 2x308
2"
1195 190 2x425
2"
FEATURES
Boiler
3
45°C
m
/h
bar
5
1,6
0,12
10
2,7
0,41
15
3
0,7
20
5
0,8
30
2 x 3
2x 0,45
40
2 x 5
2x 0,8
5
1,6
0,14
10
2,7
0,45
15
3
0,78
PACKAGING (mm)
E
F
Length Width High
355
180
450
180
570
180
1"
240
740
1" 100
240
1025
1" 100
240
1255
ENGLISH
Pool
3
m
/
Bar
h
10
0,14
15
0,24
20
0,29
15
0,39
20
0,48
25
0,59
10
0,14
15
0,24
20
0,29
WEIGHT
Kg
210
1,2
210
1,7
210
2,4
270
5,6
270
7,2
270
9