1. Brief description

The MSI-FB-PB100 module serves to connect a safety switching device to the PROFIBUS-DP according
to EN 50170. The gateway can be operated by any standard C0 master in the cyclical data exchange. It
also supports acyclic connections. The system is designed so that safety functions of the connected de-
vices (e.g. MSI100/200) inside the device cannot be influenced by establishing a connection to PROFI-
BUS.
The assignment of the process data can be individually adjusted to the application requirements using the
GSD file. Alternatively, a gateway DTM will be developed which ensures integration into FTD
environments. The GSD file (with the communication characteristics of the Profibus Gateway) can be
found at www.leuze.com.
The PROFIBUS address is set using a button and optionally a device connected to the S-PORT (PC,
memory stick, actuator). Termination of PROFIBUS on the module is not provided and must take place
using appropriate connectors if required.

2. Terms and definitions

PROFIBUS-DP
PROFIBUS-DPV1
DP master
Master class 1
Master class 2
DP slave,
DP standard slave
DPV1 slave,
S7 slave
Type files / GSD
PROFIBUS bus system with DP protocol. DP stands for distributed peripherals. The
main tasks of PROFIBUS-DP is fast cyclical data exchange between the central DP
master and the peripherals.
PROFIBUS-DPV1 is an extension of the DP protocol. This also enables acyclic
exchange of parameter, diagnostics, control and test data.
A master that behaves according to standard EN 50170, volume 2, PROFIBUS,
with the DP protocol is called DP master.
A Master Class 1 is an active device at the PROFIBUS-DP. Cyclical data exchange
with other devices is one characteristic. Typical Master Class1 are PLCs with a
PROFIBUS-DP connection.
Devices of this type are engineering, project planning or operating devices. They
are used during commissioning or for maintenance and diagnostics for configuring
the connected devices, evaluating measured values and requesting the state of the
device.
A slave that is operated at the PROFIBUS bus with the PROFIBUS-DP protocol and
behaves according to standard EN 50170, volume 2, PROFIBUS, is called DP slave.
The MSI-FB-PB100 is a DPV1 slave with the following characteristics:
• Supports the S7 model (diagnostic alarms, process alarms)
• Parameterizable
• Reading/writing data records
Device master data (GSD) contain DP slave descriptions in a uniform format. The
use of GSD simplifies the project planning of the master and the DP slave.