MAINTENANCE

Do These Procedures When You End Your Work
NOTE: Always engage the parking brake before
servicing the machine.
Check the batteries and add distilled water as needed.
The correct level is within 1/4 inch of the bottom of the
tube in each cell.
CAUTION: Tap water may contain contami-
WARNING: Lead acid batteries generate
Use a clean cloth and wipe the surface of the machine.
Charge the batteries. See the instructions in the section
of this book called "How To Charge The Batteries".
These Maintenance Procedures Must Be Done
Every Week:
WARNING: Maintenance and repairs must be
CAUTION: To prevent damage to the ma-
CLARKE TECHNOLOGY Operator's Manual -Fusion 20 Burnisher
nants that will damage batteries.
Batteries must be re-filled with
distilled water only.
gases which can cause an explo-
sion. NO SMOKING. Always wear
eye protection and protective
clothing when working near
batteries.
done by authorized personnel
only. Keep all fasteners tight.
chine, and discharge across the
tops of the batteries, do not fill the
batteries above the bottom of the
tube in each cell. Wipe any acid
from the machine or the tips of
the batteries. Do not add acid to
battery after installation.