Note: store only the addresses of the
external door stations to which the user
can be connected. Don't store the ad-
dresses of external door stations belong-
ing to different buildings even if in the
same installation.
Buttons 1,2,3,4 and 5.
These buttons can be used to:
make intercommunicating calls;
- to call users of different apartments it is
necessary to store in each button of your
monitor the address of the user you wish to
call pressing that button (codes from 001
to 200).
- to call other videointercoms installed in the
same apartment (local intercommunicating
service), it is necessary to store in the
buttons 1, 2, 3, 4, 5 of each monitor always
the code 000; starting from button 1 and
going on until you have programmed, with
the code 000, as many buttons as are the
videointercoms installed in the apartment
(max 6 units) you wish to call; automatically
by pressing buttons 1,2,3,4,5 of one unit
you will call the unit whose internal address
is related to the pressed button according
to table 3. For example if you press the
button 3 from the videointercom whose
intercommunicating address is 002 you
will call the user with intercommunicating
address 003.
monitoring external door stations (it is
suggested to use button
to monitor the
st
1
external door station) to enable this
feature store the address of the external
door station (codes from 231 to 250).
optional functions operated by means
of the actuators art.2281; to enable this
functions store the address of the actuator
to be operated (codes from 211 to 220).
To make the programming it is necessary:
enter the programming mode following
the instructions described in " Enter the
programming mode ";
a - keep pressed for more than 4 seconds
the button you wish to program; yellow
LED starts flashing;
b -enter the 3 digit of the code or address
you wish to store following the procedure
reported on the paragraph "Entering
codes or addresses";
c -press the button
; an acknowledge
tone will be heard and the yellow LED
lights-ON continuously;
repeat phases a-b-c to program other
buttons or exit the programming mode by
hanging up the handset; yellow LED turns-
OFF.
Notes.
- In each button can be stored only one code
or address.
- Intercom conversations or connections with
To make the programming easier and to remind your self the stored codes, please fill in the following table
users and external stations of other buildings will
not be possible if digital exchanger art.2273 is
installed.
Programming the number of ringing call
The videointercom can receive 4 different calls that
can be changed as indicated in the procedure
below. The default programming values and the call
sequence are shown in table 1.
All programming operations must be carried out
with the handset in idle position.
Keep pressed the button "
seconds; the yellow LED turns ON and you hear
the ring tone that was programmed for calls from
external door station.
a - press the button " " repeatedly to select the
ring tone.
b - press the button "
" to confirm and go on to
select the number of rings.
c - press the button " " as many times as the
desired number of rings (once = 1 ring; 4 times =
4 rings).
d - press the button "
" to confirm and go on to
program the ring tone for intercom calls.
If you want to change the other two tone rings (call
from other user or floor call), you must repeat
steps a-b-c-d.
Pick up and close the handset for exit the pro-
gramming mode; yellow LED turns-OFF.
Adjusting the volume
With the handset in idle position, you can adjust 4
volume levels for all ring tones, as indicated below:
press the button "
" for 4 seconds; the yellow
LED turns ON and you hear the external door
station ring tone;
hold the button "
" pressed and release it when
you hear the desired volume;
pick up and close the handset for exit the pro-
gramming mode; yellow LED turns-OFF.
The volume levels are stored and will be used for the
next calls.
More programming operations for
specific functions
How to program secondary user addresses
( additional programming operation that does not
depend on the programming operations of user
and internal station addresses)
The following programming operation allows you to
save 4 additional user addresses on the same
videointercom (i.e.: exchanger function, video-
intercom installed in common area with multiple
users, etc.).
N.B.: videointercom must be programmed also
with the internal common address as specified in
the following.
To make the programming it is necessary:
enter the programming mode following the
instructions described in " Enter the programming
mode ";
keep pressed the button "
seconds; yellow LED starts flashing;
again keep pressed the button "
than 4 sec.; yellow LED starts quickly flashing;
enter the 3 digit of the 1st user secondary
address (codes from 1 to 200) following the
procedure reported on the paragraph "Entering
codes or addresses";
press the button
address and move to the 2nd user address; an
acknowledge tone will be heard;
enter the 3 digit of the 2nd secondary user
address and confirm by pressing button
proceed entering the 3rd and 4th secondary
" for more than 4
user addresses consumer (if necessary) or to
press twice the "
the common internal address;
enter the 3 digit that compose the common
internal address to the 4 new user addresses
(codes from 000 to 007) following the procedure
of the paragraph "Entering codes or
addresses".
Note: the internal common address has to be
unique and different from you address him in-
side eventually programmed on other
videointercoms and/or intercoms that has the
same user address;
to press "
of programming; an acknowledge tone will be
heard and the yellow LED lights-ON continu-
ously;
pick up the handset for exit the programming
mode.
Note : If you want to make intercom calls, you must
program the call buttons with the codes of the
users you want to call.
Example
How to program three videointercoms with user
addresses 101, 102 and 103; from which user
103 should receive also calls addressed to user
101 and 102; user 101 and 102 should receive
only calls addressed to them.
- User 101 must be programmed only with user
address 101 and internal address 000.
- User 102 must be programmed only with user
address 102 and internal address 000.
- User 103 must be programmed with user ad-
dress 103, internal address 000, 1
address 101, 2
nal common address 001 being the internal ad-
dress of videointercoms 101 and 102 already
programmed to 000.
" for more than 4
" for more
to confirm the present
" to pass to the insertion of
" to confirm and to return of choice
st
secondary
nd
secondary address 102, inter-
Mi 2425