Locking Environmental Enclosure
Gently lower bay door. Using key (G) rotate door locks clockwise until key cannot turn. Make sure that the key has
9
fully rotated to seal enclosure. If key does not fully rotate, door lock may need to be adjusted for a looser seal. See
step 9-1 below for door lock adjustment.
NOTE: Gasket seal of bay door must be fully compressed to allow for a water tight seal. Test seal of door by
inserting a sheet of paper in between the door seal and the enclsosure seal. If the sheet of paper is easily removed,
door lock may need to be adjusted for a tighter seal. See step 9-1 below for door lock adjustment.
CAUTION
• Be careful not to pinch your fi ngers when opening and
closing bay door.
Door Lock Adjustment
To allow for a tighter seal, loosen top nut of door locks 1/4" then tighten bottom nut of door locks against lock tab.
9 -1
To allow for a more loose seal, loosen bottom nut of door locks 1/4" then tighten top nut of door locks against lock
tab.
FRONT OF BAY DOOR
NUMBER OF LOCKS
ON DOOR MAY VARY
FROM ILLUSTRATION
TOP NUT
15 of 50
ISSUED: 07-12-10 SHEET #: 061-9056-8 03-05-13
G
BOTTOM NUT