Thick Tapered Gasket
(for thin-walled vessel style
lavatory installations)
Washer
2. Install the Touch-Activated Drain
If present, remove the protective plastic cap from the drain and
discard.
Remove the nut, washer, and gasket from the drain body.
Apply a bead of plumbers putty or other sealant around the
underside of the flange according to the sealant manufacturer's
instructions.
For drains with metal stoppers: Close the drain and rotate the
drain body until the logo is positioned horizontally.
Insert the drain into the drain hole and press into place.
Slide the gasket (tapered side up) onto the drain body.
Slide the washer over the threads on the drain body.
Thread the nut up the drain body until snug against the
underside of the lavatory. Use care not to rotate the drain while
tightening the nut.
Using a wrench, tighten the nut.
Remove any excess putty or sealant.
Connect the P-trap to the drain body.
1032026-2-D
Flange
Drain Body
Tapered Gasket
Nut
4
Kohler Co.