C.Wiring
1) Connect to appropriate power supply, the voltage should comply with the
rated voltage of the products.
2) Earth the machine well.
3) Wiring must be handled by a professional technician according to the
circuit diagram.
4) Set leakage protector according to the local code for wiring (leakage
operating current ≤ 30mA).
5) The layout of power cable and signal cable should be orderly and not
affecting each other.
D.Switch on after finishing all wiring construction and re-checking.
VI. Operation instruction
Picture for keys
Symbol
Designation
Power ON/OFF
Press to power on or off the heat pump
Mode
Press to select Smart/Silence mode
Heat/Cool/Auto
Press to shift among cooling, heating and auto
Up/ Down
Press to set desired water temperature