5.8 Multiplying factor (frequency meter)
5.9 Dividing factor (frequency meter)
5.10 Decimal point (frequency meter)
5.11 Display mode (frequency meter)
4
It can be set from 00.0001
up to 99.9999.
"0" is not accepted!
It can be set from 00.0001
up to 99.9999.
"0" is not accepted!
The decimal point defines
the resolution in the select-
ed measuring range 1/min
or 1/sec
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
Value conversion and
display in 1/s
Value conversion and
display in 1/min
5.12 Max. time to wait until "0" is displayed
(frequency meter)
This parameter indicates how long it takes, when
measuring is active, until "0" is displayed.
5.13 End of programming
6. Technical data
Supply voltage
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
10 – 30V DC/max. 40 mA
with inverse-polarity protection
6 digits, red 7 segment
LED display, height 8 mm
[0.31 in.]
EEPROM
Programmable, npn or pnp
(sinking or sourcing) for all
inputs
appr. 5 kΩ
MN05401004E