Inductive sensor
Data for application in connection with hazardous
areas
Equipment protection level
Equipment protection level Gb
Type of protection
CE marking
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
IECEx certificate
IECEx marking
Standards
Effective internal inductivity
Effective internal inductance
Maximum permissible ambient temperature T
Equipment protection level Da
Type of protection
CE marking
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
Effective internal inductivity
Effective internal inductance
Maximum permissible ambient temperature T
Equipment protection level Mb
Type of protection
Certificates
Appropriate type
IECEx certificate
IECEx marking
Standards
Effective internal inductivity
Effective internal inductance
2
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Gb , Da , Mb
intrinsic safety
0102
NJ 10-22-N...
PTB 00 ATEX 2048 X
¬ II 2G Ex ia IIC T6...T1 Gb
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx PTB 11.0037X
Ex ib IIC T6
IEC 60079-0:2004 , IEC 60079-11:2006
C
≤ 130 nF
i
A cable length of 10 m is considered.
L
≤ 100 µH
i
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 16 V , I
= 25 mA , P
i
i
T6 : 73 °C (163.4 °F)
T5 : 88 °C (190.4 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 16 V , I
= 25 mA , P
i
i
T6 : 69 °C (156.2 °F)
T5 : 84 °C (183.2 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 16 V , I
= 52 mA , P
i
i
T6 : 51 °C (123.8 °F)
T5 : 66 °C (150.8 °F)
T4 : 80 °C (176 °F)
T3 : 80 °C (176 °F)
T2 : 80 °C (176 °F)
T1 : 80 °C (176 °F)
at U
= 16 V , I
= 76 mA , P
i
i
T6 : 39 °C (102.2 °F)
T5 : 54 °C (129.2 °F)
T4 : 61 °C (141.8 °F)
T3 : 61 °C (141.8 °F)
T2 : 61 °C (141.8 °F)
T1 : 61 °C (141.8 °F)
intrinsic safety
0102
NJ 10-22-N...
PTB 00 ATEX 2048 X
¬ II 1D Ex ia IIIC T135°C Da
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
C
≤ 130 nF
i
A cable length of 10 m is considered.
L
≤ 100 µH
i
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 16 V , I
= 25 mA , P
i
i
at U
= 16 V , I
= 25 mA , P
i
i
at U
= 16 V , I
= 52 mA , P
i
i
at U
= 16 V , I
= 76 mA , P
i
i
intrinsic safety
NJ 10-22-N...
IECEx PTB 11.0037X
Ex ia I
IEC 60079-0:2004 , IEC 60079-11:2006
C
≤ 130 nF
i
A cable length of 10 m is considered.
L
≤ 100 µH
i
A cable length of 10 m is considered.
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@us.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
= 34 mW ,
i
= 64 mW ,
i
= 169 mW ,
i
= 242 mW ,
i
= 34 mW : 100 °C (212 °F)
i
= 64 mW : 100 °C (212 °F)
i
= 169 mW : 80 °C (176 °F)
i
= 242 mW : 61 °C (141.8 °F)
i
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
NJ10-22-N-E93-Y245590