Descargar Imprimir esta página

Sime MURELLE EQUIPE 220 BOX ErP Manual Del Usuario página 59

Ocultar thumbs Ver también para MURELLE EQUIPE 220 BOX ErP:

Publicidad

Idiomas disponibles

Idiomas disponibles

3.3
ACCESS TO
INSTALLER'S
PARAMETERS
For access to the installer's parameters,
press simultaneously the keys
or 2 seconds (3 fig. 12).
For example, the parameter PAR 23 is
visualised on the display of the control
panel in the following way:
The paramet er s scr oll for war ds and
backwards with the key
and
the default parameters can be changed
with the keys
and
.
The standard visualisation returns automa-
tically after 60 seconds, or by pressing one
of the control keys (2 fig. 12) excluded the
key RESET.
3.3. 1
Replacing the board or
RESETTING parameters
If the electronic board is replaced or reset,
it is necessary to configure PAR 1 and PAR
2 by associating the following values to
each type of boiler to be able to restart the
boiler:
GAS
MODEL
220 BOX ErP
METHANE
330 BOX ErP
(G 20)
440 BOX ErP
550 BOX ErP
220 BOX ErP
PROPANE
330 BOX ErP
(G 31)
440 BOX ErP
550 BOX ErP
FAST CONFIGURATION
PAR DESCRIPTION
1
Combustion configuration
and
2
Hydraulic configuration
3
Timetable 2 programmer
4
Pressure transducer disabler
5
Assignment of auxiliary relay AUX
and
6
Luminous bar indicating presence
of voltage
7
Allocation of SIME HOME channels
8
Fan rpm Step ignition
9
Long chimneys
10 Remote control option setting
11
Correction values external sensor
12 Backlighting duration
13 Modulating pump speed
PAR 1
14
Setting second input TA
7
15
Cascade address
16
ModBus address
17
ModBus communication configuration
19
Type circuit
15
D.H.W. - HEATING
PAR DESCRIPTION
20
Minimum heating temperature Zone 1
21
Maximum heating temperature Zone 1
22
Heating curve slope Zone 1
23
Minimum heating temperature Zone 2
24
Maximum heating temperature Zone 2
25
Heating curve slope Zone 2
26
Minimum heating temperature Zone 3
27
Maximum heating temperature Zone 3
28
Heating curve slope Zone 3
∆t heating circuit
29
30
Post-circulation heating time
31
Maximum heating capacity
32
Zone 1 pump activation delay
33
Start-up delay
34
Additional source activation threshold
35
Boiler antifreeze
36
External sensor antifreeze
37
Band saturation
flowmeter modulation
38
D.H.W. post-circulation time
39
Anti-legionella
(only D.H.W tank))
PARAMETERS INSTALLER
RANGE
UNIT OF
MEASUREMENT
-- = ND
1 ... 31
-- = ND
1 ... 14
1 = DHW + Recirc. pump
2 = DHW
3 = Recirculation pump
0 = Disabled
1 = Enabled 0-4 BAR
2 = Enabled 0-6 BAR
3 = Enabled 0-4 BAR (NO ALL 09)
4 = Enabled 0-6 BAR (NO ALL 09)
1 = Remote supply
2 = Recirculation pump
3 = Automatic load.
4 = Remote alarm NC
5 = Heat pump
6 = Zone 2 valve
0 = Disabled
1 = Enabled
0 = Not assigned
1 = Circuit 1
2 = Three-zone circuit
0,0 ... 81
rpmx100 0, 1 from 0, 1 to 19,9
0 ... 20
1 = SIME HOME
2 = CR 53
3 = RVS 43. 1 43
4 = RVS 46.530
5 = RVS 61.843
-5 ... +5
-- = Always
sec. x 10
0 = Never
1 ... 199
-- = None
Au = Automatic mod.
30... 1 00 = % Settable
modulation
-- = Contact TA
5... 1 60 = Input 0... 1 0VDC
-- = Not enabled
0 = Master
1...7 = Slaves
-- = Not enabled
1...31 = Slaves
1 ... 30
0 = Two zones
1 = Three zones
RANGE
UNIT OF
MEASUREMENT
PAR 64 OEM ... PAR 21
PAR 20 ... PAR 65 OEM
3 ... 40
PAR 64 OEM ... PAR 24
PAR 23 ... PAR 65 OEM
3 ... 40
PAR 64 OEM ... PAR 27
PAR 26 ... PAR 65 OEM
3 ... 40
10 ... 40
0 ... 199
30 ... 100
0 ... 199
0 ... 10
-- , -10 ... 40
0 ... +20
-5 ... +5
-- = Disabled
0 ... 100
0 ... 199
0 = Disabled
1 = Enabled
INC/DEC
DEFAULT
UNIT
SETTING
=
=
"- -"
=
=
"- -"
=
=
1
=
=
1
=
=
1
=
=
1
=
=
1
0,0
1 from 20 to 81
%
1
0
=
=
1
°C
1
0
1
3
%
10
Au
--
--
--
--
1
--
--
1
--
--
1
25
--
--
0
INC/DEC
DEFAULT
UNIT
SETTING
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
°C
1
20
Sec.
10
30
%
1
100
10 sec.
1
1
Min.
1
3
°C
1
"- -"
°C
1
3
°C
1
-2
%
1
100
Sec.
1
0
--
--
0
ES
ENG
59

Publicidad

loading