Fig. 13 --- Solid Piece of Wood Placement
Window Sash
Window Sash
Sealing Strip
Fig. 14 --- Seal Strip Adhesion
Step 6 —Installation of the cabinet
A. Align one hole in the bottom of the cabinet with one hole in
the bracket assembly. Secure the cabinet to the bracket using
(3) 1/4" screws provided. Repeat the same procedure on the
opposite side of the cabinet. See (Fig. 15).
B. Ensure the "L" shaped mounting channel is positioned in front
of the sash. The bottom channel of the cabinet should be
positioned in the track provided on the bracket assembly. Pull
the window down until it rests just behind the front of the "L"
shaped mounting channel. See (Fig. 16).
C. Check to make sure that the cabinet is slanted slightly
downward on the outside. If necessary, re- -adjust support
bracket as shown in (Fig. 12).
Step 7 —Secure Shutters
A. Carefully slide the air conditioner back into the cabinet.
(Please seek assistance for this procedure).
B. Reinstall the slide- -out- -chassis security screws (removed
earlier) on both sides of the cabinet (see Fig. 12). Secure the
top of the frames to the window sash with (2) 3/4" screws.
C. Now, secure bottom frame of shutters using one shutter clamp
and one 3/4" screw on each side (see Fig. 12).
Step 8 —Reinstalling Front Panel Assembly
A. Position the front panel on the cabinet starting at the top. The
front panel lock tabs must be inserted into the retaining slots in
the cabinet. Repeat this procedure on all sides.
B. Secure the front grille to the cabinet using the Philips screws
removed earlier (see Fig. 6).
Step 9 —Complete the installation
A. Cut the foam to fit the opening between the top of the inside
and outside window (see Fig. 18).
B. Some installations may require additional sealing around
the window and air conditioner. Check for any air leaks and
seal where necessary.
Solid Piece Wood
(If required)
A06542
A06543
C. In very humid areas, the water removal may be excessive
enough to overflow the unit or increase the noise of the air
conditioner. If this occurs, you may wish to attach a drain hose
(not included) to the drain plug allowing condensations to run
off conveniently (see Fig. 19).
NOTE:
Fresh Air ventilation is usually kept in the closed
position. Use only when clearing smoke and/or odors from the
room. Pull to open (see Fig. 20).
1/4" Screws
Fig. 15 --- Secure the Cabinet
Fig. 16 --- Mounting Channel
3/4" screws
Coil
Fig. 17 --- Security Screw Detail
Fig. 18 --- Foam Fitting
8
A06544
Window Sash
Seal
"L"Shaped
Mounting
Channel
A06545
Seal
"L"Shaped
Mounting
Channel
Security Screw
A06546
Foam
A06547