MOD.
...........................................................................................
.. .
TECHNICAL SPECIFICATIONS
- Air fitting: G 1/4" M
- Product delivery fitting (version SP): G 1/4" M
- Maximum air pressure: 5 bar (73 psi)
- Maximum product pressure (SP version): 5 bar (73 psi)
Feed
Ø
SP version
1.0
Gravity
Suction
1.3
SP version
Gravity
Suction
1.5
SP version
HD
Gravity
Suction
1.7
SP version
HD
Gravity
Suction
1.9
SP version
HD
Gravity
Suction
2.2
SP version
HD
Gravity
Suction
2.5
SP version
HD
** Product flow was calculated with water, setting the recommended regulations.
.. .
U SE
Spray guns int the 9000 HTE series have been designed for the application of finishing colours in all those sectors requiring
high quality finishing and low fumes emission.
The instrument is not suitable for use with abrasives or products containing acids or petrol of any kind.
To obtain the best results, the following instructions must be followed carefully:
1. When possible, use an air pipe with a minimum internal section of ø 8 mm (0.3").
2. Make sure the compressed air used is perfectly filtered removing all water, oil or other impurities (for example, by installing
an Asturomec filter regulator ref. 61131 and Asturomec coalescent microfilter ref. 61201, or by the more complete and efficient
WALCOM TD
PRO multifunctional filter and heating unit).
3
.. .
ADVICE FOR CORRECT USE
1. The distance between the spray gun and the surface to be painted must be set between 150 and 200 mm (5.9"- 7.9").
If the spray gun is working at too low a pressure and at too high a distance, il will not perform to the best of its capacity.
2. The jet from the spray gun must always be perpendicular to the surface being
painted and the paint must be applied in horizontal strokes. Any eventual shift from
this position when spraying will result in an uneven application of the paint layer.
3. Correct viscosity of the paint is between 15 and 25 sec. Coppa Ford n. 4. These
values depend on the application in question and the measure of the nozzle in use.
.. .
FORM OF THE FAN
- Air pressure too low
- Product viscosity too high
- Quantity of product too high
Adjust the air pressure, product quantity and spray aperture
until obtaining a regular imprint as in fig. C
Delivery
**Product load
pressure
324 Gr/min.(11.4 oz/min.)
228 Gr/min.(8 oz/min.)
348 Gr/min.(12.3 oz/min.)
242 Gr/min.(8.5 oz/min.)
410 Gr/min.(14.5 oz/min.)
260 Gr/min.(9.2 oz/min.)
2.5-3.0 bar
(36-43 psi)
432 Gr/min.(15.3 oz/min.)
280 Gr/min.(9.9 oz/min.)
502 Gr/min.(17.7 oz/min.)
294 Gr/min.(10.4 oz/min.)
588 Gr/min.(20.8 oz/min.)
328 Gr/min.(11.6 oz/min.)
- Air pressure too high
- Product viscosity too low
- Quantity of product too low
15
9011 / 9010 / 9010 sp HTE
9011 HD
. ..
ADJUSTMENTS
- Working pressure: 2.5-3.0 bar (29 psi)
- Fan: Fully open
- Air: Fully open
- Product: 3-3.5 turns
Air consumption
Fan dimensions
at 20 cm (7.9")
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
180-220 Lt./min (6.4-7.8 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
220-240 Lt./min (7.8-8.5 CFM)
- Regular jet
20 cm (7.9")
18 cm (7.1")
22 cm (8.7")
18 cm (7.1")
24 cm (9.5")
20 cm (7.9")
26 cm (10.2")
20 cm (7.9")
26 cm (10.2")
22 cm (8.7")
26 cm (10.2")
22 cm (8.7")