Troubleshooting - Kobalt VT6389 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CARE AND MAINTENANCE
6. Check the safety valve by performing the following
steps:
a. Restore power to unit; turn pressure switch to the
AUTO position. Run until unit reaches 90 psi.
Turn pressure switch to OFF position.
b. Wearing safety glasses and hearing protection,
pull the ring on the safety valve to release
pressure from compressor tank. Protect yourself
from fast-moving air being released; do not allow
fast-moving air to be directed toward your face
(See Figure 3).
c. The safety valve should automatically close at
approximately 40-50 psi. If the safety valve does
not allow air to be released when you pull on the
ring, or if it does not close automatically, it MUST
be replaced.
7. Check belt for signs of excessive wear. If belt shows
signs of wear, replace it. Check belt for proper
tension / alignment.
TECHNICAL SERVICE
For information regarding the operation or repair of this product, please call 1-888-3KOBALT
(1-888-356-2258).
OPERATION
CHECK OIL LEVEL
DRAIN TANK
CHECK AIR FILTER
CHECK SAFETY VALVE
CLEAN UNIT
CHECK BELT TIGHTNESS
CHANGE OIL*
* Change oil after fi rst fi fty (50) hours of operation then perform oil changes every three (3)
months.

TROUBLESHOOTING

PROBLEM
Low discharge
pressure
MAINTENANCE SCHEDULE
DAILY
POSSIBLE CAUSE
1. Air demand exceeds
pump capacity
2. Restricted air intake
3. Air leaks (fittings,
tubing on compressor,
or plumbing outside of
system)
3
WEEKLY
CORRECTIVE ACTION
1. Reduce air demand or use a compressor with
more capacity.
2. Clean or replace the air filter element.
3. Listen for escaping air. Apply soap solution to
all fittings and connections. Bubbles will appear
at points of leakage. Tighten or replace leaking
fittings or connections. Use pipe thread sealant.
16
MONTHLY
3 MONTHS

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0268707

Tabla de contenido