NOTES:
■
The flexible exhaust hose allows placement of the air
conditioner between 23¾" and 64½" (60 cm and 163 cm)
from window or door
■
Confirm you are using the correct size air conditioner for the
space to be cooled, per sizing recommendations, below:
Area to be cooled
Square Footage
Up to a 10 "x 20" Room
200
300
Up to a 15 " x 20" Room
Up to a 20 "x 20 "Room
400
500
Up to a 20 "x 25" Room
NOTE:Adjust BTUs to room use and location:
■
Shaded room reduce by 10%
■
Sunny room increace by 10%
■
For occupancy over two people add 600 BTUs per
person
■
Kitchen use add 2,000 BTUs
Vertical Slide Widow
- - - - - - - - - - - - - - - - - - -
A WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Location Requirements
Capacity needed
(BTUs)
8,000
10,000
12,000
14,000
Electrical Requirements
■
-
-
-
-
■
■
4
Horizontal Slide Window
NOTES:
■
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
23¾" (60 cm).
■
Do not block the air outlet.
■
Provide easy access to the grounded 3 prong outlet.
The portable air conditioner should be dedicated to a 115V, 60
Hz, 15-amp fuse grounded 3 prong outlet.
The use of a time-delay fuse or time-delay circuit breaker is
required.
All wiring must comply with local and the national electrical
codes and be installed by a qualified electrician. If you have
any questions, contact a qualified electrician.