Polar Diagram & Area Covered
The SZI 1015-T modulator/radiator emits the infra-red light in a lobar shape. The IR intensity decreases
with the distance. When a receiver leaves the area covered by the radiator, transmission is interrupted.
Receivers without squelch will produce a hissing noise, receivers with squelch will mute.
20˚
30˚
40˚
50˚
60˚
70˚
80˚
90˚
10˚
105m
98m
91m
84m
77m
70m
63m
56m
49m
42m
35m
28m
21m
14m
7m
10˚
26dB
40dB
20˚
30˚
40˚
50˚
60˚
70˚
80˚
90˚
23