HEATER INSTALLATION
1. Remove coupling from heater cap.
2. If 1" diameter heater is to be used, remove smaller rubber gasket, if ¾"
diameter heater is used, use both gaskets (small inside the large).
3. Slide coupling over heater tube.
4. Insert heater through gasket and clear cap.
5. Screw on coupling to clear cap and tighten.
6. Screw clear cap with heater installed onto heater module. HAND TIGHTEN
ONLY.
7. Start water flow through module.
8. Turn on heater and adjust.
CAUTION
AT NO TIME OPERATE HEATER WITHOUT MODULE FULL OF WATER.
DAMAGE WILL RESULT TO BOTH HEATER AND HEATER MODULE
IF HEATER IS OPERATED WHEN DRY. DO NOT LUBRICATE GASKETS.
AF-93
MODEL
HOW TO CHARGE THE CHEMICAL CHAMBER
1. Unscrew module cap.
2. Remove cup spring and chamber plug.
3. Remove chamber from module.
4. Fill chamber with coarse granular carbon or other media that will not pass
through the chamber screen.
5. Rinse carbon by letting water run down chamber through open end until
clear.
6. Install chamber in filter module. Make sure chamber fits onto center hub in
bottom of filter module. Chamber should protrude about
7. Replace chamber plug.
8. Install cup spring, large end over chamber plug.
9. Before replacing module cap make sure O-ring is clean, lubricated with
Lifegard Silicone and is in place. HAND TIGHTEN ONLY.
HOW TO CLEAN AND RECHARGE
1. Shut off pump.
2. Place clamps over inlet and outlet tubes below the level of the module cap.
3. Remove cap from module.
4. Remove cup spring, chamber plug and chamber from module.
5. Empty carbon or other media from chamber.
6. Fill chamber with new carbon or other media. Make sure filtering media will
not pass through the chamber screen.
7. Rinse carbon by letting water run down chamber through open end until
clear.
8. Before replacing module cap, remove the O-ring and thoroughly clean it,
and lubricate the O-ring with Lifegard silicone and replace cap on the
module and HAND TIGHTEN ONLY.
9. Remove clamps from inlet and outlet tubes and start pump.
HEATER MODULE
CHEMICAL FILTER
1
/
" above module.
16
HEATER
R175022
COUPLING
GASKET ½" FOR COUPLING
R175023
GASKET ¾" FOR COUPLING
R175008
½" CLOSE NIPPLE USED TO
CONNECT "T" MODEL MODULES
R270313 - ¾" CLOSE NIPPLE
R172008 - 3" FILTER CAP
R172009 - CAP O-RING
R172014
R172043 - CUP SPRING
CARTRIDGE
PLUG
R175056 - CAP RETAINER CHAMBER
R175029 - RETAINER CHAMBER
R175054 - RETAINER CHAMBER
R175055 - RETAINER CHAMBER
R175008 - ½" CLOSE NIPPLE USED TO
R270313 - ¾" CLOSE NIPPLE
R175021
3" CLEAR HEATER CAP W/COUPLING
R172009 CAP O-RING
AF-93 ONLY
AF-93-19 ONLY
AF-93-29 ONLY
CONNECT "T" MODULES