When connecting the inverter to the power source, it is recommended to use the largest diameter
wire available in the shortest length possible.
The table below recommends the AWG Wire size for each inverter not to exceed .2 volts loss in
the cables connected to the inverter when it is operated at Maximum capacity.
See the Table below for recommendations
distance from battery
distance from battery
distance from battery
AWG Wire Sizes
Conductor
Diameter Inches
0.46
0.4096
0.3648
0.3249
0.2893
0.2576
0.2294
0.2043
0.1819
0.162
0.1443
0.1285
0.1144
0.1019
0.0907
0.0808
0.072
0.0641
0.0571
0.0508
1000w unit
2ft
4
AWG Gauge
2500w unit
2ft
3
AWG Gauge
4500w unit
2ft
1
AWG Gauge
Conductor
Diameter mm
11.684
10.40384
9.26592
8.25246
7.34822
6.54304
5.82676
5.18922
4.62026
4.1148
3.66522
3.2639
2.90576
2.58826
2.30378
2.05232
1.8288
1.62814
1.45034
1.29032
4ft
6ft
4
3
4ft
6ft
1
0
4ft
6ft
000
0000
10ft
0
10ft
0000
10ft
N/R