• 3 level temperatures: comfort, economy and frost protection
• Frost protection functionality
• Battery low
• Alarm of missing radio frequency communication on the
receiver
• Room temperature calibration
• Automatic boiler switch ON for radio communication er-
rors (missing communication between receiver and trans-
mitter).
OPERATING INSTRUCTIONS
At the fi rst installation the thermostat, the time and the day
of the week needs to be set (see encoder paragraph). After
this, a desired thermostat status must be selected (see
the encoder paragraph). When in AUTO mode the heating
request follows the programmed heating pattern and the
desired room temperature selected.
When in PARTY mode the heating request is ON all the
time according the desired room temperature selected.
When in OFF mode, the heating request is OFF all the time
(frost protection is ON).
The thermostat is pre-programmed with a default heating
pattern (see table below); however this can be modifi ed to
suit individual needs (see encoder paragraph)
Pre-programmed heating pattern
Day
Monday (day 1)
06:00
Tuesday (day 2)
06:00
Wednesday (day 3)
06:00
Thursday (day 4)
06:00
ON
OFF
ON
08:00
16:00
22:00
08:00
16:00
22:00
08:00
16:00
22:00
08:00
16:00
22:00
Day
Friday (day 5)
Saturday (day 6)
Sunday (day 7)
Other factory set values are:
• Comfort temperature: 21°C
• Economy temperature: 16°C
• Frost protection temperature: 5°C
• Hysteresis OFF: 0,4°C (boiler switch OFF at 0,4°C above
the target)
• Hysteresis ON: 0,2°C (boiler switch ON at 0,2°C below
the target)
LOW BATTERIES
The two supplied batteries will last for approximately 1 year
under a normal usage. When the batteries are low, the re-
lative icon will appear on the display. It is better to change
the batteries on time in order avoid any lack of heating sup-
ply during the day.
Follow the correct positioning of the batteries according to
the internal transmitter battery box indications.
Every time the batteries are removed the transmitter loses
only the time. The programmed times, the set temperat-
ures and the transmitter coupling code are maintained
OFF
memorized.
19
ON
OFF
ON
06:00
08:00
16:00
08:00
11:00
16:00
08:00
11:00
16:00
OFF
22:00
23:00
EN
23:00