CONTROL PADS ON THE DEHUMIDIFIER
NOTE: The control panel of the unit you purchased may be slightly different according to the
models.
Timer on/off
indicator light
9 9
On
Continuous
operation on
Off
indicator light
10 10
Comfort dehumidifying
TIMER
CONT.
operation on
indicator light
Pump operation
on indicator light
PUMP COMFORT FILTER
Fig.1
1 1
2 2
Control pads
When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
PUMP Pad(on some models)
1 1
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer
to the next pages for removing the collected water.
Do not use this operation when the outdoor temperature
O
O
is equel to or less than 0 C (32 F).
COMFORT Pad(optional)
2 2
Press to activate the comfort dehumidifying operation.
NOTE: On this operation,the unit can not be set
humidity level.
3 3
FILTER Pad
The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.
4 4
TURBO Pad
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
Auto defrost operation on
Bucket full
11 11
indicator light
indicator light
7 7
8 8
Defrost Full
6 6
POWER
High fan
indicator light
Ion operation
TURBO
ION
indicator light
Clean filter
indicator light
4 4
5 5
3 3
ION Pad(optional)
5 5
Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.
6 6
POWER Pad
Press to turn the dehumidifier on and off.
8 8
: Down/Up Pads
7 7
Humidity Set Control Pads
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the
pad and set to a lower
percent value(%).
For damper air, press the
pad and set a higher
percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
4 4
CONTROL PADS ON THE DEHUMIDIFIER
TIMER Pad
9 9
Press to initiate the Auto start and Auto stop feature,
in conjuction with the
and
pads.
10 10
CONTINUE Pad
Press to activate the c ontinuous dehumidifying operation.
11 11
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(
5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is
full, or when the bucket is removed or not replaced
in the proper position.When the setting humidity is
reached, the unit will be shut off automatically.
For some models,the fan motor will continue
operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full -- Empty the bucket.
E3- Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
Eb- Bucket is removed or not in right position-- Replace the
bucket in the right position.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
5 5