Troubleshooting:

Symptoms
No reaction from the system while the
gear is switched to reverse.
No reaction on display while there are
obstacles within the detecting area.
There is no obstacle within the detect-
ing area, but constant warning and
voice prompt occurs.
There is no obstacle within the detect-
ing area, but fixing distance is shown
on screen.
Description
Replacement Sensor System (Includes speaker, control box, sensors and cable)
Speaker for Sensor Kit
Control box for Sensor Kit
Sensors with Cable (qty. 4)
Power cable for Sensor Kit
Declaration of conformity:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Possible Causes
No power input.
Improper connection of the sensor or monitor.
Excessive dirt built up on the sensors.
The distance from the ground is detected.
Replacement Parts/Accessories
Solutions
Ensure the power and trigger wires
are securely connected and the main
harness is securely connected to the
control box
Ensure sensors are connected securely
and in sequence.
Clean the sensors.
Adjust the angle of sensors. Also en-
sure the sensors are installed with the
top facing up.
Part No.
EC1004-SK
EC1005
EC-CB04
EC-RS04
PC-1004