LED Bliking Codes
Sensor Error
Damper Error
Wall Control Error
Filter Maintenance
Learning Mode
Damper error
2 blinks
Remove the obstacle. Plug
unit back, note down the
Runtime % setting, and turn it
to "Test". The damper should
now work normally. Put the
Run time % back to its
Wall control
error
4 blinks
Wall control does
not work
Learning mode
Very slow blink
Unit does not
provide the
required airflow
1 blink
2 blinks
4 blinks
Slow blink
(2 s ON, 2 s OFF)
Very slow blink
(1 s ON, 10 s OFF)
Perform a visual
inspection. Is
NO
there an
obstacle
hindering
damper
movement?
YES
previous value.
There is a short circuit in the wall
control wiring. Inspect wiring at the
wall control and on the terminal
block. Restore any connection that
may be causing a short circuit. Is
the problem fixed?
Inspect the connections at
the control and at the
terminal block. Restore any
wrong connection.
Is the problem fixed?
During the first 48 hours of operation, the unit is gathering environmental
This can be triggered by a change of setting, a power shortage, or powering
unit back. This blinking code is not an error.
Are filter(s) grille,
and/or hood
clogged?
YES
Perform
maintenance.
You are not sure
that your ventilation
needs are met.
Sensor error
1 blink
Are the damper
wires in good
condition and well
connected to the J5
connector on the
electronic board?
YES
Try connecting an other damper to the board
(without completely installing it). Plug unit back,
note down the Runtime % setting, and turn it to
"Test". If the damper does not move within
15 seconds, replace the electronic board. If the
damper now works, replace it.
Test the wall
NO
control using a
new wire. Is
the problem
Test the wall
NO
control using a
new wire. Is
the problem
fixed?
data.
Are the speed
NO
switches on the
board properly
positionned?
NO
Refer to Section 3.
15
Review the Speed, Mode
and Runtime % settings.
Refer to Section 3.
Verify the W and Y
connectioons.
Replace the electronic
board
Restore the connections or,
if the wires are damaged,
NO
replace the damper. Plug
unit back, note down the
Run time % setting, and turn
it to "Test". The damper
should now work normally.
Put the Run time % back to
its previous value.
The wall control
NO
damaged. Test
using an other
fixed?
wall control.
If there is no short,
NO
the wall control may
be damaged. Test
using an other wall
control.
YES
Is the measuring tool
accurate? Try using a
different tool.
NO
Calibrate tool.