2.2 SETTING
APPLIANCES WITH MECHANICAL VALVE (FIG.7)
SWITCHING ON PILOT LIGHT
-
Open gas valve behind appliance.
-
Turn temperature adjusting knob(Fig. 7).
-
Open door of appliance.
-
Press the pilot-light button until the pilot light comes on and at the same time press the ON pushbutton for about
20 seconds until all the air has left the pipe and the pilot light is burning.
-
Check that the pilot light is on with the appliance door open and light the main burner.
LIGHTING THE MAIN BURNER AND ADJUSTING TEMPERATURE
KNOB REFERENCE
1
2
3
4
5
6
7
8
OIL TEMPERATURE °C
110
121
133
146
158
171
183
195
Pag. 17
-
Turn knob to position 1 to light burner.
Adjust the temperature by turning the
-
knob from position 1 to position 8. For
correct temperatures, see temperatures
table.
-
Observe the data shown in the table,
AVOID OVERHEATING OIL.