11. Press the A key to show "AUPf0" (time of auto-off).
12. Press the D key to change the time of auto-off (parameter 0=never off).
13. Press the A key to back to normal weighing mode.
Parameters setting using keys of crane scale
1. When power on and self detecting, keep pressing
shows "CAL SP".
2. Press the
3. Press the
the
key to set the value.
4. Press the
5. Press the
6. Press the
7. Press the
8. Press the
9. Press the
10. Press the
11. Press the
12. Press the
key once the display shows "SET".
key once the display shows "d x", (x means division), press
key to show the capacity of the crane scale.
key to modify the capacity value.
key to show "fLT 00" (filter parameter 0 – 4).
key to set the filter parameter.
key to show "rng 1" (zero tracking parameter).
key to set the zero tracking value.
key to show "AUPf0" (time of auto-off parameter).
key to set the auto-off time (0=never off).
key to back to normal weighing mode.
key until display