Descargar Imprimir esta página

Beninca RI.624 Libro De Instrucciones página 10

Centralita a microprocesador por

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Dip-switch functions
DSW1 Operating mode for input "P.P."
OFF: Open/STOP/Close/STOP sequence
ON: Open/Close sequence
DSW2 Function "Automatic closure"
OFF: Disabled
ON: Enabled
For safety reasons, the function "Automatic closure" is always disabled after a control signal at the "STOP" inputs, or if an obstacle is detected by a rev.
sensor.
DSW3 "Multi-user" function: the input "P.P." does not stop the motor during the opening phase. At completion of the opening phase, the input "P.P" is enabled for
the gate closure.
OFF: Disabled
ON: Enabled
DSW4 "Pre-warning" function: the flashing light is activated 3 seconds before the starting of each operation.
OFF: Disabled
ON: Enabled
DSW5 Photocell intervention in the opening phase: if the photocell beam is interrupted, the motor is stopped. The operation starts again as soon as the photocell
beam is no longer obscured.
OFF: Disabled
ON: Enabled
DSW6 "Pedestrian" function: the input "Open" controls the partial opening.
OFF: Disabled
ON: Enabled
DSW7 Operating mode of the "Pedestrian" function
OFF: The input "Open" controls only the opening phase
ON: The input "Open" has the same functions as the input "P.P."
DSW8 Operating mode of the "Indicator lamp of open gate"
OFF: Normal operation ON/OFF
ON: Flashing operation: in the opening phase the indicator lamp flashes slowly. At completion of the opening, the indicator is on with fixed light, while in the
closing phase it flashes quickly.
Programmable functions
The functions for which it is possible to select from a range of values are set using the programming pushbutton (PROG.) together with the dip-switches. The pre-
set values are indicated with "(def.)". To store the programmable functions in the memory, position the dip-switches as indicated in the table, then press the
"PROG." button for at least 2 seconds. The "PROG." LED will go out and then come back on for about 2 seconds to indicate the settings have been stored. Once
programming has been completed, return the dip-switches to their original positions.