The special decoder 1039/80 can be used in IperVoice system to activate electrical loads by means of
double exchange relay whose operation can be:
Bistable.
Toggle timed.
Possible applications include: Switching staircase light on, operating supplementary lock, opening gates,
etc. The load can be controlled directly, since this is a power relay (see technical specifications).
According to its configuration and setting, the Special Decoder activates the relay depending on system
events (see system manual).
§
Every external push button can activate only one relay depending on how the special decoder has
been programmed.
The device is powered by POE, but it's possible to add an external power supply fro emergency situation in
order to ensure the device operation also if the system doesn't work (in this case the relay can be activated
only by the external button).
Led function
Blinking slow:
Steady on:
TeRMiNALS DeScRipTioN
V+
External Power supply (positive), optional
V-
External Power supply (negative), optional
PB1 External push button 1
PB2 External push button 2
[
NO Relay 1 normally open contact
OUT 1
NC Relay 1 normally closed contact
C
Relay 1 common contact
[
NO Relay 2 normally open contact
OUT 2
NC Relay 2 normally closed contact
C
Relay 2 common contact

TechNicAL SpecificATioN

Rated Input POE (RJ45:
Rated Input +V –V:
Rated relay contact:
4
Acquisition of the IP address in progress
IP address obtained
44V
44 - 56V
, 50mA
, 5A o 250V~, 5A
30V