Troubleshooting

Problem
Cylinder rod will not move
Slow cylinder shaft speed while
extending and retracting
Leaking Cylinder
Leaking pump shaft seal
Oil leaking out air vent

Replacement Parts

Component
Phone (800) 828-5500 to order replacement parts or a complete Parts Manual (have your full model number and serial number ready). Parts Manual
downloads are also available free of charge at www.troybilt.com.
Cause
1. Shipping plugs left in hydraulic hoses.
2. Pump gear sections damaged.
3. Damaged relief valve.
4. Hydraulic lines blocked.
5. Incorrect oil level.
6. Damaged directional valve.
7. Blocked directional valve.
8. Un-level ground; hydraulic fluid not reaching pump.
1. Gear sections damaged.
2. Excessive pump inlet vacuum.
3. Slow engine speed.
4. Damaged relief valve.
5. Incorrect oil level.
6. Contaminated oil.
7. Directional valve leaking internally.
8. Internally damaged cylinder.
9. Log Splitter not on level ground.
1. Broken seals.
2. Scored cylinder.
1. Broken drive shaft.
2. Engine/pump misalignment.
3. Gear sections damaged.
4. Poorly positioned shaft seal.
5. Plugged oil breather.
1. Reservoir fluid overfilled
2. Operating on un-level ground.
1. Disconnect hydrauic hoses, remove shipping plugs, reconnect hoses.
2. See authorized service dealer.
3. See authorized service dealer.
4. Flush and clean hydraulic system.
5. Check Oil Level.
6. See authorized service dealer.
7. Flush and clean hydraulic system.
8. Move log splitter to level ground.
1. See authorized service dealer.
2. Make certain pump inlet hoses are clear and unblocked, use short,
large diameter inlet hoses.
3. See authorized service dealer.
4. See authorized service delaer.
5. Check oil level.
6. Drain oil, clean reservoir, and refill.
7. See authorized service dealer.
8. See authorized service dealer.
9. Move log splitter to level ground.
1. See authorized service delaer.
2. See autorized service dealer.
1. See authorized service dealer.
2. Correct alignment as necessary.
3. See authorized service dealer.
4. See authorized service dealer.
5. Make certain reservoir is properly vented.
1. Check fluid level.
2. Move to level ground or position air vent to uphill side.
Part Number
727-05103
727-05104
727-04156
720-04088
726-04079
753-08457
Remedy
Description
Valve/Cylinder Hose
Pump/Valve Hose
Inlet & Return Hose
Grip, .625
Hose Clamp (not a direct
replacement, service part only)
Clutch Bumpers Kit (6)
6
7
9