Cable coding simulation (PP)
The electric vehicle charger cables are encoded so that they do not
exceed the vehicle maximum admissible current. Using the selector switch
⑦ the different cable coding can be simulated, from not coded to 64 A.
When testing a charger with a hose, this selector switch is not operative
and the current is the maximum charger current.
Phase presence and sequence
After vehicle charging simulation has started (Statuses B, C or D), the
led indicator lamps ② will display the phases that are present and the
led indicator lamps ③ will display their sequence. In the case of single-
phase chargers, only L1 will be present.
Phase sequence Phases present
6