Technical data sheet
Power:
Connection:
Charging terminals:
Grounding terminal:
Measuring category:
Current surge category:
Operating temperature:
Contamination grade:
Relative humidity:
Protection Rating:
Protection class:
Vehicle status simulation (CP):
Cable coding simulation (PP):
Installation protection test:
Cable length:
External dimensions
Maintenance
No unauthorised person must open the VIARIS TESTER. There are no
replaceable components inside the tester.
No special maintenance is required.
Clean the tester with a soft cloth dampened in soapy water or alcohol.
Then leave the tester to dry completely before use.
6 V
4 x 1.5 V LR6/AA
Type 2 pin as specified in EN 62196-
2:2012
8 A / 230 V~ (1800 W)
Functional
CAT II as specified in EN 61010-2-030
II as specified in EN 61010-1
From 0 ºC to +40 ºC
2
Annual mean < 75%. Specific values 95%
IP40 as specified in EN 60529
II. Double insulation
Statuses A, B, C and D (short circuit of CP
to ground and diode)
Open, 13 A, 20 A, 32 A and 64 A
AC and DC
1 metre
210.6
11