Powder Coated & Stainless Steel Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
6
Pilasters and Panels with Stirrup Brackets (Standard)
Pilasters located at walls should be mounted first. Start at one end and install a panel, then a pilaster. Continue alternating until
installation is complete. When installing in an alcove or in-corner, use an alcove bracket to secure the pilaster to the panel.
Check to make sure the pilasters are plumb and level to each other. The pilaster height can be adjusted with the leveling bolt that
was placed at the bottom of the pilaster (see page 5 for attaching leveling bolt).
Pilasters at Wall
When installing pilasters at walls, the gaps range
from 1/2" to 1-1/4" (13mm to 32mm). Refer to your
submittal drawing for your gap sizes.
Slide the shoe onto the bottom of the pilaster and
use a piece of tape to keep the shoe positioned
A
above the mounting hardware . Make sure the shoe
mounting hole is facing inside the stall and that the
hole is towards the top .
Position the pilaster so the mounting bracket(s)
sits on the inside of the floor "L" bracket(s) while at
B
the same time placing the pilaster within the wall
brackets . Secure the pilaster mounting bracket(s) to
the floor "L" bracket(s) using the #14 x 5/8" screw(s)
provided .
Using the bracket as a template, drill Ø3/16" holes
C
through the pilaster at each pilaster bracket hole .
Secure the pilaster to the bracket using the
#14 x 5/8" screws provided .
10
3/21/2018
Pilasters with Panels
Refer to your submittal drawing and leave the appropriate
gaps. Standard gap is 1" (25mm) between the panel and
wall and 1/2" (13mm) between the panel and pilaster.
A
Place the panel on the spacer and insert the panel into the
wall brackets .
Slide the shoe onto the bottom of the pilaster and use
B
a piece of tape to keep the shoe positioned above the
mounting hardware . Make sure the shoe mounting hole is
facing inside the stall and that the hole is towards the top .
Position the pilaster so the mounting bracket(s)sits on the
C
inside of the floor "L" bracket(s) while at the same time
placing the brackets around the panel . Secure the pilaster
mounting bracket(s) to the floor "L" bracket(s) using the
#14 x 5/8" screw(s) provided .
Spacer 12" (305mm)
Using the bracket as a template, drill Ø3/16" holes through
D
the panel at each panel bracket hole . Secure the panel to
the bracket using the #14 x 5/8" screws provided .
Bradley • HDWT-INSTR-009 Rev K; ECN 17-14-007
Installation