Cleaning And Care - Delta 100LF-WF Serie Manual De Instrucciones

Ocultar thumbs Ver también para 100LF-WF Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1/8" (3.18mm)
5
Maintenance
If faucet leaks from under handle:
Remove handle and ensure cap (1) is tight.
If leak persists–SHUT OFF WATER
SUPPLIES. Replace Ball Assembly (2)–
Repair Kit RP70 and Cam & Packing (3)–
Repair Kit RP61.
If faucet leaks from spout outlet:
SHUT OFF WATER SUPPLIES. Replace
Ball Assembly (2)–Repair Kit RP70 and
Seats & Springs (4)–Repair Kit RP4993.
If faucet exhibits very low flow
A. Remove and clean Aerator (5), or
B. SHUT OFF WATER SUPPLIES. Clean
Seats and Springs (4) of any debris.
If spray attachment does not
function properly:
SHUT OFF WATER SUPPLIES. Remove
Diverter Assembly (6) and clean.
If condition persists–SHUT OFF WATER
SUPPLIES. Replace Diverter Assembly (6)–
Repair Kit RP63136.
If faucet leaks from base of spout:
SHUT OFF WATER SUPPLIES. Remove
spout and replace Spout O-Rings (7)–Repair
Kit RP25.
6

Cleaning and Care

Care should be given to the cleaning
of this product. Although its finish is
extremely durable, it can be damaged
by harsh abrasives or polish. To clean,
simply wipe gently with a damp cloth
and blot dry with a soft towel.