Adjusting The Volume; Fixing The Unit - AVIRE Memco Memcom 492 021 Guia De Instalacion

Mps
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Connections to the MPS unit
Insert a small flat head screw driver in the clamp section of the screw-less connector to open the clamp, insert the wire in
the hole and remove the screwdriver to clamp the wire in place secure the wire.
1, 2, 3 MPS

Adjusting the volume

Memco is a brand of Avire
4, 5, 6, 7, 8 MPS
Adjusting the volume
The unit volume can be adjusted using a small flat head
screwdriver. Insert the screwdriver in the volume adjustor
on the back of the unit. Turn anti- clockwise to increase the
volume and clockwise to decrease the volume.
If feedback can be heard, reducing the volume may reduce or
remove the feedback.
Unit status LED
The status LED shows when the unit is correctly installed and also when an
alarm has been activated from the station, as detailed below:
LED status
LED not lit- unit is not functional
RED LED Dimly lit- unit is functional
RED LED Brightly lit- alarm has been activated

Fixing the unit

The unit can be fixed to the wall by the fixing holes at the top and the bottom
of the unit, using the M4.2 self-drilling screws provided. The unit can then be
slid on and off of these screws without the need to unscrew.
Avire Limited
Avire Ltd
Unit 1 The Switchback
Unit 1, The Switchback
Gardner Road
Gardner Road
Maidenhead
Maidenhead
Berkshire
Berkshire SL6 7RJ, UK
SL6 , UK
T:
01628 540100
T:
01628 540 100
F:
01628 621 947
F:
01628 621 947
E:
sales.uk@avire-global.com
E:
sales.uk@avire-global.com
W:
www.memco-global.com
W:
www.memco-global.com
W:
www.avire-global.com
W:
www.avire-global.com

Publicidad

Tabla de contenido
loading

Productos relacionados para AVIRE Memco Memcom 492 021

Tabla de contenido