6. Inspect impeller and volute insert for wear.
The impeller may develop sharp edges after use. Use care when cleaning around impeller to avoid
getting cut.
Replace impeller and/or volute insert if wear is significant.
7.
Reinstall the volute insert, pump housing (using bolts removed earlier), drain plug and priming plug.

Draining the Pump

Risk of injury or property damage from fire.
Do not remove priming plug, drain plug, pump housing or inlet or discharge hose fittings when
pump is hot. Hot water and/or vapor inside could be pressurized.
If the pump is subject to freezing temperatures, pump housing must be thoroughly drained of any water to
prevent damage from freezing.
1.
Allow the unit to cool completely.
2. Remove drain plug and priming plug from pump housing and drain any water left in the pump.
3. Make sure the suction and discharge lines are free of water.
4. Reinstall the drain and priming plug.

Transporting the Pump

1.
Allow unit to cool completely.
2. Empty the fuel tank or close the fuel valve.
3. Disconnect the spark plug wire from the spark plug and place wire where it cannot contact the plug.
4. Make sure the pump is kept level to reduce the possibility of oil or fuel leakage.
5. Ensure the pump is securely strapped down in the transport vehicle to prevent it from sliding or tipping.
6. Move the pump to its operating location and then fill the fuel tank.
Do not refuel the pump in or on the transport vehicle.

Storage

Risk of injury or property damage from fire.
Do not remove priming plug, drain plug, pump housing or inlet or discharge hose fittings when
pump is hot. Hot water and/or vapor inside could be pressurized.
Store the pump in a well-ventilated area away from furnaces, stoves, water heaters, clothes dryers,
or other appliances that have a pilot light or other ignition source (heat, flame, sparks, etc.) because
they can ignite fuel vapors.
If pump is being stored for more than 30 days:
1.
Allow unit to cool completely.
2. Remove drain plug and priming plug from pump housing and drain any water left in the pump.
3. Clean inside of pump housing. Refer to
4. Coat inside of pump with a light film of oil to reduce corrosion.
5. Tape up suction and discharge ports to prevent anything from accidentally entering the pump.
6. Refer to and follow instructions in the engine manufacturer's owner's manual for engine storage.
7.
Cover pump and engine.
8. Store in a clean, dry area.