Remote Control Commands Extension - Promax OP-170-E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.5 Remote control commands extension

Due to the new available functions, it is necessary to add several items to the MO-170
remote control command list. These new commands are described below:
Name
Message
*SHPd<cr>
SHP
*?SHP<cr>
*SBTd<cr>
SBT
*?SBT<cr>
*NOId<cr>
NOI
*?NOI<cr>
*CNRddd<cr>
CNR
*?CNR<cr>
*SIGd<cr>
SIG
*?SIG<cr>
*ECOd<cr>
ECO
*?ECO<cr>
*EAMdaaaa<cr>
EAM
*?EAMd<cr>
*EPHdpppp<cr>
EPH
*?EPHd<cr>
*EDOdsffff<cr>
EDO
*?EDOd<cr>
*EDLdtttt<cr>
EDL
*?EDLd<cr>
Page 8
Answer
Description and Format
Select modulator pulse shaping mode.
'd' ASCII coded digit.
0: BYPASS, 1: STANDARD, 2: USER
*SHPd<cr>
Ask for the current modulator pulse shaping mode.
'd' as before.
Select modulator pulse shaping beta value.
'd' ASCII coded digit
0: β=4, 1: β=8, 2: β=16, 3: β=32
*SBTd<cr>
Asks for the current modulator pulse shaping
beta value.
'd'
as before.
Select noise generator state.
'd' ASCII coded digit
0:OFF, 1:ON
*NOId<cr>
Asks for the noise generator state.
'd' as before.
Set C/N value when noise generator is ON.
'ddd' ASCII coded digits
C/N in dBx10 (030 to 400)
*CNRddd<cr>
Asks the current C/N value.
'ddd' as before.
Set COFDM signal ON/OFF.
'd' ASCII coded digits
0:ON, 1:OFF
*SIGd<cr>
Asks for the COFDM signal generation state.
'd' as above.
Set Echo generator ON/OFF.
'd' ASCII coded digits
0:OFF, 1:ON
*ECOd<cr>
Asks for the echo generator value.
'd' as before.
Set echo amplitude.
'd' echo number (0 to 5)
'aaaa' amplitude in dBc x 10
*EAMaaaa<cr>
Asks for the echo amplitude.
'd' and 'aaaa' as before.
Set echo phase
'd' echo number (0 to 5)
'pppp' phase in DEG x 10.
*EPHpppp<cr>
Asks for the echo phase
'd' and 'pppp' as before.
Sets echo Doppler frequency.
'd' echo number (0 to 5)
's' sign + / -
'ffff' frequency in Hz x 10.
*EDOsffff<cr>
Asks for the echo Doppler frequency.
'd' ,'s' and 'ffff' as above.
Set echo delay time.
'd' echo number (0 to 5)
'tttt' delay time in µs x 10
When 'd' = 0, the delay is internally fixed at 0 µs
regardless of the field 'tttt' .
*EDLtttt<cr>
Asks for the echo delay.
'd' and 'tttt' as above.
OP-170-E USER'S MANUAL
06/2006

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido