Spare Parts; Electrical Diagram; Disposal; Ce Declaration - PLYMOVENT MFE Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
Symptom
Problem
Dust or smoke
Pollution of the
coming out of
facility.
the filter cover.
Machine
Machine does
makes a
not function
sputtering
properly.
noise.
Vibrations in
Machine not
the machine.
steady.
8

SPARE PARTS

The following spare parts are available for the machine (refer to
exploded view Fig. I on page 50).
Article no.
Description
MFE general
0000101885
Ionisation wire for FIS (10 pcs)
0050101210
Hose set (Ultra)Flex for mounting on mobile unit
0101050010
Ioniser FIS
0102080030
Aluminium pre/final filter SAF
0104060010
Activated carbon final filter SCF
0302250010
Capacitor 0,5 μF, 660V
0324150120
Control lamp 28V, yellow
0326000520
PC board HT MFE/SFE
0328100020
Safety switch, 2 poles
0328410130
Relay MC2A
0334100200
Transformer 50W/24V 115/230/400V
0340000110
Fuse 2,0 A
0609590110
Starlock 22 mm
0612010220
Adjusting ring 19x1
0708020140
Aluminium fan wheel 50Hz
0708020150
Aluminium fan wheel 60Hz
0801400010
Housing FAN 14/28/MNF/mobile units, motor side
0803010080
Insulator FCS
0803011090
Insulator FIS
0805030010
Wheel Ø 250 mm black
0805040010
Swivel castor Ø 125 mm with brake
0805040050
Swivel castor Ø 125 mm without brake
0806014020
Cover star knob M8
0840101030
Bush Ø 203 mm
9821430000
Collector FCS
9821430010
HT transformer MFE
0507250010/010513/G MFE
Possible cause Solution
Ioniser and/or
Clean the filters and
collector
mount them
saturated or
correctly. Ref. 6.2
mounted
and 6.2.4.
incorrectly.
High voltage
Replace high voltage
transformer
transformer.
defective.
High voltage PC
Replace high voltage
board defective.
PC board.
Short-circuit in
Check and repair.
the ioniser and/
or collector.
Bad contact in
Check and repair.
the ioniser and/
or collector.
Ioniser and/or
Mount the filters
collector
correctly. Ref. 6.2.4.
mounted
incorrectly.
Ioniser and/or
Clean the filters. Ref.
collector
6.2.
seriously
polluted.
Not properly
Let the filters dry
dried ioniser
thoroughly after
and/or collector.
cleaning.
Broken
Replace ionisation
ionisation wires
wires.
in the ioniser.
Bent lamelles in
Straighten lamellas.
the collector.
Ref. 6.2.3.
Metal particles in
Remove metal
ioniser and/or
particles and clean
collector.
the filters.
Imbalance in the
Clean the extraction
extraction fan.
fan.
Article no.
Description
9824000060
Filter cover MFD/MFE incl. outlet grid
9824000110
Mounting set safety switch MFE
9824000210
Axle
9850040090
Wheel covers yellow MFD/MFS/MFE (2 pieces)
MFE 400V/3ph/50Hz
0320000100
Motor 0,75kW, 230-400V/3ph/50Hz
0328260080
Motor protection switch MPS 1.6-2.5A
MFE 230/3ph/50Hz
0320000100
Motor 0,75kW, 230-400V/3ph/50Hz
0328260090
Motor protection switch MPS 2.5-4.0A
MFE 230/1ph/50Hz
0321012030
Motor 0,75kW, 115-230V/1ph/50-60Hz
0328260100
Motor protection switch MPS 4.0-6.3A
MFE 115/1ph/50Hz
0321012030
Motor 0,75kW, 115-230V/1ph/50-60Hz
0328260200
Motor protection switch MPS 10-16A (CSA+UL)
9

ELECTRICAL DIAGRAM

Refer to the separately supplied electrical diagram.
10

DISPOSAL

After life of the machine, dispose it of in accordance with
federal, state or local regulations.

CE DECLARATION

EC declaration of conformity for machinery
(according to Annex II A of the Machinery Directive)
We, Plymovent, Wezelkoog 11, 1822 BL Alkmaar, the
Netherlands, herewith declare, on our own responsibility, that
the machinery:
- MFE
which this declaration refers to, is/are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC 2004/108 EC
- LVD 2006/95 EC
and is/are in conformity with the following harmonized
standard(s) and/or other such normative documents +
amendments, if any:
- EN ISO 12100-1:2003 (safety of machinery)
- EN ISO 12100-2:2003 (safety of machinery)
- EN ISO 13857:2008 (safety distances)
- EN-IEC 60335-1
- EN-IEC 60335-2-65
Alkmaar, the Netherlands, May 1, 2013
Ir. F. Coehoorn
Vice President Research & Development
EN - 16

Publicidad

Tabla de contenido
loading

Tabla de contenido