Safety Instructions
• Maintain adequate clearances of 50-60cm around air
openings into the combustion chamber, clearances from
combustible material, provisions for accessibility and for
combustion and ventilating air supply. Keep the trap area
clear and free from combustible materials, gasoline, and
other flammable vapors and liquids. The appliance is not
to be used in locations where flammable vapor or
explosive dust is likely to exist.
• Do not obstruct the flow of combustion and ventilation air.
• Keep the ventilating openings of the cylinder enclosure
free and clear from debris.
• Clean the trap with a water damp cloth, if necessary.
• A maximum of a 20 lb. LP-Gas cylinder shall be used.
• The LP-Gas cylinder supply system must be arranged for
vapor withdrawal and the cylinder must include a collar to
protect the cylinder valve.
• The trap shall be used outdoors only in a well ventilated
space and shall not be used in a building, garage, or any
other enclosed area.
• The LP-Gas cylinder must be disconnected and removed
from the appliance, if the appliance is stored indoors.
• LP-Gas cylinders must be stored outdoors in a well-
ventilated area out of reach of children.
• Disconnected cylinders must have threaded valve plugs
tightly installed and must not be stored in a building, garage,
or any other enclosed area.
• The pressure regulator and hose assembly supplied with
this appliance must be used for connection to the LP-Gas
cylinder. Replacement pressure regulators and hose
assemblies must be specified by the manufacturer.
• Avoid improper use of extension cords. Keep connections
away from moisture and avoid damage to the cord.
• If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid hazard.
• Do not store near heat or fire or where temperature may
exceed 60°C.
• PPG Regulator and Hose Assembly Class A
• Rated Working Pressure: 2.74 kPa
Outlet Pressures: 2.50 kPa to 3.5 kPa
Velocity: 165 ft/min to 275 ft/min
Visit www.mosquitomagnet.com