For examples of practical applications that can be implemented on the
e.sylink, refer to the e.sybox installation manual.

Pressure sensor:

e.sylink allows the use of 1 remote pressure sensor, directly on the
4-pole connector J31.
For further information refer to the e.sybox installation manual.

2- INSTALLATION

e.sylink must be installed in closed environments, it is not suitable for
open-air installations or where there is a high level of humidity.
Before connecting e.sylink to the supply voltage, make all the neces-
sary wiring, connecting the INPUTS and OUTPUTS in the desired
configuration, optionally connect the pressure sensor and set the
desired input and output configurations on the e.sybox (refer to the
e.sybox installation manual).
At this point power the e.syLink with the supply voltage, as described
in Figure 3. Figure 3 shows, just as an example, a supply wiring, using
a 24 VDC feeder for assembly on a DIN bar.
14
Figure 4: Example of e.sylink power supply connection
At start all the leds are lit for 2 seconds, in order to check their correct
operation.
In the event of malfunction the FAULT leds will light up, as described
in Table 5.
Now make the connection with one e.sybox or more, as described in
chapter 3.
ATTENTION: In order to connect e.syLink to e.syBox check that the
FW version of e.sybox is 4.xx or higher. To check the FW version, re-
fer to the e.sybox installation manual. In the case of a previous version
update the e.sybox to version 4.xx or higher as described in chapter 4,