Descargar Imprimir esta página

Panasonic CS-E7GKEW Instrucciones De Operación página 5

Ocultar thumbs Ver también para CS-E7GKEW:

Publicidad

Idiomas disponibles

Idiomas disponibles

FEATURE OPERATION
FEATURE OPERATION
FEATURE OPERATION
FEATURE OPERATION
TO SELECT FAN SPEED
• There are 5 fan speeds, as well as
automatic*.
* For automatic fan speed, the speed
of the indoor fan is automatically
adjusted according to the operation.
TO ADJUST AIRFLOW DIRECTION
• Keeps the room ventilated.
• There are 5 options for vertical airfl ow
direction.
• If automatic vertical airfl ow direction
has been set, the louvers swing up/
down automatically.
• In heat mode, the air blows horizontally
for a while, then starts to blow
downwards.
• Do not adjust the vertical airfl ow
direction louvers by hand.
• Horizontal airfl ow direction louver is
manually adjustable.
TO MONITOR AIR QUALITY
• This setting enables the patrol sensor
to automatically detect the air quality.
• When the air quality is unsatisfactory,
e-ion operation will start automatically.
TO ENJOY CLEAN AIR
• This setting provides clean air by producing
negative ions to attract dust which will then
be captured at the positively charged e-ion
fi lters.
TO ENJOY QUIET ENVIRONMENT
• This setting provides a quiet environment by
reducing the airfl ow noise.
TO ACHIEVE TEMPERATURE QUICKLY
• This setting enables the desired
temperature to be reached quickly.
• POWERFUL operation will run for 20
minutes, after that this operation will stop
automatically.
,
,
modes and could be cancelled by pressing the respective button
again.
and
or
activated at the same time.
and
operations could be activated even when the
air-conditioner is turned off. In this condition, once e-ion indicator
is ON, the unit will operate with AUTO fan speed and air swing.
and
operations are available in all
and
operations could not be
TIMER SETTING
TIMER SETTING
TIMER SETTING
TIMER SETTING
TO SET THE TIMER
• When you want the air conditioner to turn ON or OFF
automatically at a preset time.
Select ON
Set the
or OFF
desired
timer.
time.
To cancel ON or OFF timer, press
or
, then press
• When ON Timer is set, the unit may start earlier (up
to 30 minutes) before the actual set time in order to
achieve the temperature you preferred.
• The timers repeat daily once set.
• If there is a power failure, you can restore the
previous setting (once power is resumed) by pressing
the
button.
• If the timer is cancelled, press
previous setting.
● The timer is based on the time set in the remote
control.
● You can set your preferred time for ON and OFF
timers.
Hints
■ Temperature setting of 1°C higher in cool mode or
2°C lower in heat mode than the desired temperature
performs a 10% power saving.
■ To reduce power consumption during cool mode, close
the curtains to prevent the sunlight and heat from
coming in.
■ To disable the PATROL operation during unit start with
, press and hold
release.
To reset, press
again for 5 seconds then
release.
■ To set either 12-hour (am/pm) or 24-hour time
indication, press and hold
seconds.
■ To dim the indicator display on the air conditioner:
Press and hold
for 5 seconds.
To reset, press
again for 5 seconds.
■ To switch the temperature setting to °C or °F, press and
hold
for approximately 10 seconds.
● To turn off the air conditioner, press
Confi rm
the setting.
.
to restore the
for 5 seconds then
for approximately 5
.
5

Publicidad