Astralpool WATERHEAT EQUIPADO 20kW Manual Tecnico página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WATERHEAT SERIES · WATER/WATER SYSTEM
What's the meaning of the index lights on the panel?
The function of the LED on the panel is showing below:
INDEX LIGHT
NAME
FILTRATION
PUMP
HEAT
ALARM
The meaning of the LED display
The LED usually shows temperature, if it shows "SHr", it means the temperature sensor is short,
and "OPE" means the temperature sensor is open. The temperature and the alarm code (Axx)
will show alternately when in the alarm state.
The code is showing below:
CODE
SIGNIFICATION
A11
External alarm
Water temperature
A21
probe error
A99
Over probation time
How to set the temperature?
Press the key "set" for at least 2 seconds, then enter the state of temperature setting, here the
LED displays the setting temperature, then using "▲" key or "▼" key can change the
parameter (the key "▲" adds 0.1°C, the key "▼" minuses 0.1°C, press and hold it over 0.5
seconds can add or minus rapidly). After setting, press "set" again, then exit the state of
parameter setting. (The setting temp range is limited by the parameters F13 and F14; please
refer to the senior operation). Pressing the key "M" in the setting process means cancel and
exit, but the setting value will not be saved.
Advanced Operation
Press the key "M" and hold it for 5 seconds, and if you have set the password, the LED display
the "PAS" to hint you to enter the password, you can use the key "▲" and "▼" to enter the
password, if the password is correct, the LED will display the parameter code, use "▲" or "▼"
to select the parameter code. Pressing the "set" key can make it to show the value of the
parameter after select the parameter, here you use "▲" or "▼" to set the parameter(pressing
the key and not release can add or minus rapidly), then press the "set" key to return to the state
of showing parameter code after finishing setting. Pressing the key "M" can exit the parameter
setting state when display the parameter code, pressing the key "M" means cancel when in the
process of setting parameter, and the parameter will not be changed.
© ASTRALPOOL 2018 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
LIGHT
Equipment is heating, after the delay
of turning on the internal water
pump.
Equipment is heating, after the delay
of turning on the internal water
pump.
- - -
EXPLANATION
Alarm from external alarm signal, please refer to the
internal parameter code "F50"
Disconnection or short circuit (showing "OPE" or
"SHr".
If you have set the probation time F87, the alarm
occurs when the accumulative running time is over
probation time and the controller cannot work.
ENGLISH
FLASH
Filtration pump is on and the
equipment is timing for turning
on the internal water pump.
- - -